19
Dymax BlueWave® LED Flood System User Guide
Operating in Manual Mode
Manual Mode Description
Manual Mode
means that the LED activates whenever the foot switch or the run button on the front panel is
pressed. The LED remains active only as long as the foot switch or run button is pressed. When the foot pedal
and run button are released, the LED shuts off.
Procedure
1.
Ensure the
BlueWave LED Flood
is in Manual Mode
(Figure 19). If the system is not in Manual Mode, follow
the instructions in
“Choosing an Operating Mode”.
2.
Verify that the LED Head is connected properly to the
Power supply via the Interconnect Cable.
3.
Press and hold the Footswitch or the
Button on
the front panel to activate the LED.
4.
To stop exposure, release the Footswitch or the
Button on the front panel.
NOTE:
The “LED ON” text will only appear when the
footswitch or run button is pressed.
Operating in Timer Mode
Timer Mode Description
Timer Mode
means that the LED is active for a specific time period each time the foot switch or run button is
pressed. You must set the specific time by adjusting the timer’s value on the screen. M
omentarily pressing
the foot switch or run button starts the timer and activates the LED. When the timer counts down to zero, the
shutter closes, and the timer resets to the value that you set and is ready for another exposure cycle. The
activation can be cancelled at any time during the exposure cycle by pressing the foot switch or run button.
NOTE: A timed exposure can be interrupted with the foot switch or the
button on the front panel.
Adjusting the Timer
1.
Ensure the
BlueWave LED Flood
is in Timer Mode (Figure 20). If the
BlueWave LED Flood
is not in Timer
Mode, follow the
instructions in “
Choosing an Operating Mode
”.
2.
If the time on the screen is correct, skip to Step 6. Otherwise you need to adjust the Timer to the correct
value by following the next steps.
Figure 19. Manual Mode -