12
Dymax UVCS 2.0 Light-Curing Conveyor User Guide
Conveyor Operation
1.
Install all safety accessories to protect operator from UV-light emissions.
2.
Apply power to the Conveyor and turn it on.
3.
Unlock the Speed Control Knob (Figure 13) and adjust the speed for the desired setting. The Speed
Control Knob is a 10-Turn Potentiometer and allows speed adjustment from approximately 0.9 FPM
to 32 FPM (feet per minute).
Figure 12. Conveyor Front Panel
Figure 13. Speed Control Knob
4.
If any adjustments are needed for the Belt alignment, refer to the Maintenance Section of this
manual.
5.
Adjust the height of the Lamps to the desired distance.
6.
Once all the settings (speed and Lamp height) have been properly set, the Conveyor is ready for
operation.
7.
When the Conveyor is operating and the Belt is in motion, turn the Power Supply on by closing the
Breaker(s) on both of the Pow
er Supply’s Front Panels.
8.
Turn the Irradiators on by pressing the Lamp On Button of the Master Power Supply (Figure 11). Both
the Master and the Slave Power Supplies will go through a warm-up cycle. The Blower inside the
Irradiators will turn on and the Lamps will ignite. The Lamps reach full intensity within 5 seconds
after ignition. Your UVCS Conveyor is now ready for operation.
NOTE:
The Fusion Power Supplies are interlocked with the Conveyor so that the Conveyor must be
operating and the Conveyor Belt in motion before the Lamps will ignite. This prevents Belt overheating
and damage that can result if the Belt is stationary when the Lamp is turned on.