Dymax UVCS 2.0 Light-Curing Conveyor User Guide
Troubleshooting
CAUTION!
Only qualified maintenance personnel should attempt the following procedures.
Table 2. Troubleshooting Chart for the UVCS Conveyor
Problem
Possible Cause
Testing
Corrective Action
Conveyor
is not
operating
Main-Line Circuit
Breaker deployed
Toggle Power Switch off, then
on, to reset the Circuit Breaker.
Check current rating of the Breaker
and compare to Table 4.
Improperly fastened
connections
Check all connections.
Properly fasten Power Cord.
Fuses for Motor
Controller blown
Remove Fuses from Fuse
Holders (located in the left side
of Control Box of unit) and
check with an Ohmmeter.
Replace if defective.
Belt is hung up
Inspect the Belt for any signs of
a mechanical bind.
Resolve bind and continue
operation.
Tension too low on Belt
(Power Switch will light
and Motor will turn but
the Belt does not move)
Verify the operation of the
Drive Shaft and Drive Rollers.
Use the Tracking Adjustment Knobs
to increase the tension on the Belt.
Both Knobs will have to be turned
the same amount to not affect the
alignment.
Belt tracks to
one side
Belt-Adjustment Knobs
are out of position
Visually inspect the Belt. Belt
will track to one side.
Tighten the Adjustment Knob (the
one located on the side to which
the Belt is tracking towards) until
Belt tracks straight. Only minor
adjustments should be made at
one time.
Fusion Lamp(s)
not igniting
Please reference the Fusion Lamp operator's manual for troubleshooting assistance.