The following error and acknowledgment codes are supported by the UA-1. Not all codes are
relevant to each request or command. Supported command error codes are listed for each
command.
Function
Name
Description
01
Illegal Function
Function not supported or not recognized by the
sensor.
02
Illegal Addresses
Incorrect address, address does not exist, or
address does not support write function.
03
Illegal Data Value
Data value is outside of allowed range.
04
Device Failure
Error occurred while attempting to perform the
requested action.
System Status Codes
System status codes are unique to the sensor, not Modbus protocol exceptions. System codes are
bit codes representing internal functional errors. A clear (0) bit indicates no errors were detected.
A set (1) bit indicates an error.
Contact customer support if system errors are encountered.
Bit
Decimal
Name
0
0
Direction Invalid
1
1
Direction Error
2
4
Magnetic Field High
3
8
Magnetic Field Low
Hex Values
0x0000 – No Errors
0x0001 to 0x000F – Wind direction sensor error