![DX Engineering DXE-AVA-3 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/dx-engineering/dxe-ava-3/dxe-ava-3_manual_2545499013.webp)
- 13 -
Weatherproof the coaxial cable connection using Loctite Dielectric Grease (
LCT-37534
) and if additional
weatherproofing is required for your installation, use Temflex Tape (
TES-2155
) and Vinyl Tape (
TES-
06132
) as a UV overwrap.
For the
DXE-RSEAV-1FVI
the included 120 Vac 60 Hz, to 12 Vdc wall transformer DC
power supply connects to the +12 Vdc input. The center of the 2.1mm power plug is
positive. Larger power supplies or station power may also be used provided there is an in-
line 1 ampere fast-blow fuse. The RCA phono jack on the
DXE-FVI-1
connects to the
receiver input with a customer supplied cable.
Active antenna circuitry needs a good voltage supply to operate properly. Supplied power needs to be +11.5
to +15 VDC, 25 mA minimum at each active (under load).
The
DXE-FVI-1
is not included or used in the multi-element vertical sets. Power is applied to the coax when
Bias Tee Enable internal jumpers are set in the
DXE-NCC-2
, or by the Four-Square or Eight Circle Array
Relay Unit. The AVA-3 can also be powered by a separate DC coaxial cable to the Optional DC Power type-
F connector, with internal jumpers reset; see page 8.
Coaxial Cable Feedline
A good flooded 75 Ω feedline cable is recommended for use with the
RSEAV
systems.
DXE-RG6UFQ
Flooded 75 Ω Quad Shield Coaxial Cable has improved shielding. Flooded style cables have the distinct
advantage of automatically sealing small accidental cuts or lacerations of the jacket. Flooded cable also
prevents shield contamination and has a gummy liquid inside that seals cuts or nicks, displaces water, and
can be direct buried.
The feedline carries the RF and is used to provide power for the AVA-3 Active
Matching Unit.
DXE-EX6XL-25
Compression type F connectors are recommended for
quad shield coax to ensure high quality and weather resistant feedline connections. Use
the proper tool to crimp these connectors.
To help decouple the feedline from radiated noise, bury the feedline for some distance from the antenna
when the feedline reaches the ground. A
DXE-RFCC-1
DX Engineering Receive Feedline Choke will also
ensure feedline decoupling, which may be installed in-line, preferably at the station end.
To seal out moisture, the use of Dielectric Grease is recommended for type F connectors, such as Permatex
PTX-22058
or Loctite
LCT-37534
.
Never use anti-seize on any coaxial RF or power connector.
Troubleshooting Information
When using the
DXE-RSEAV-1
Active Receive Vertical antenna, the actual received signal level will be
lower than a transmit antenna. Depending upon a few variables, including the frequency of the measured
signal, your
DXE-RSEAV-1
Active Receive Vertical is probably operating normally.
The
DXE-RSEAV-1
is designed to be a very low to no gain, low noise system for greatly improved signal-
to-noise performance over a very wide range of frequencies.