 Problem 

Possible Solution 

Bad output video quality 

 

Check the source video signal quality by connecting an analog 
monitor to the video source. If video quality is acceptable, 
connect the video source to the unit. 

 

Check that the cables are connected securely. This includes 
junction boxes and amplifier that may be used. 

 

Check that the camera settings are correct on the camera and in 
the unit. Refer to the 

HTML Edition Units User’s Guide

 for details. 

 

Check that the camera lens is clean and unobstructed. 

 

Check that the analog video signal is not being degraded due 
impedance caused by lengthy or worn cable, numerous 
connectors, ground loops interference, and so on.  

 

Check that the cable length is within specification.

 

Streaming video image is 
hanging (stopped) 

 

Confirm the unit’s video streaming settings. Refer to the 

HTML 

Edition Units User’s Guide

 for details. 

 

Refresh your browser screen (F5). 

 

Check that the bandwidth and bit rate settings of the network 
are set properly. 

 

Check that other processes and applications are not causing 
undue latency. 

 

Check that the firewall analysis or blocking is not interfering with 
the video stream and supports the required ports and 
communication protocols. 

Alarm inputs are not 
working 

 

Check the unit settings to confirm that the alarm input is 
enabled. Refer to the 

HTML Edition Units User’s Guide

 for details. 

 

Check that a proper rule for an alarm input event has been 
defined in the unit. Refer to the 

HTML Edition Units User’s Guide

 

for details. 

 

Check that the alarm input (dry contact close/open) is being 
provided by the connected device. 

 

Check that the unit is communicating through the network. 

 

Check that the alarm input wires are connected securely. 

 

Check that the alarm wires are paired in the terminal block in the 
right positions and according to requirements. 

Relay outputs are not 
working 

 

Check the unit settings to confirm that the relay output is 
enabled. Refer to the 

HTML Edition Units User’s Guide

 for details. 

 

Check that a proper rule for activating a relay output has been 
defined in the unit or activate it manually. Refer to the 

HTML 

Edition Units User’s Guide

 for details. 

 

Check the relay output wires are connected securely. 

 

Check that the relay output wires are paired in the terminal block 
according to requirements and that one wire is connected to the 
common. 

Содержание TRK-101-P

Страница 1: ...not be reproduced or reprinted in whole or in part without the express written permission of DVTEL INC DVTEL INC 65 Challenger Road Ridgefield Park NJ 07660 The contents of this manual may not be rep...

Страница 2: ......

Страница 3: ...ty to Connect the Unit to the Network 8 3 2 4 Connecting the Video Source Camera to the Unit 11 3 2 5 Configuring PTZ Camera Settings on the Encoder 12 3 2 6 Connecting the Analog Video Output to an A...

Страница 4: ...Nuts Removed 6 Figure 6 Inserting Units into Rack Mount Panel 6 Figure 7 DNA Discovery Window 9 Figure 8 DNA Assign IP Use DHCP Dialog Box 9 Figure 9 DNA Assign IP Static IP Dialog Box 10 Figure 10 Lo...

Страница 5: ...ry or death Avertissement est un message pr ventif indiquant qu une proc dure ou condition pr sente un risque potentiel de blessure ou de mort A Caution is a precautionary message that indicates a pro...

Страница 6: ...ignes de s curit les normes et les codes lectriques ainsi que la l gislation en vigueur sur le lieu d implantation des unit s Proprietary Rights and Non Disclosure This manual is delivered subject to...

Страница 7: ...en place de mesures de s curit insuffisantes Le non respect de tout ou partie des proc dures recommand es ou des messages d AVERTISSEMENT ou d ATTENTION de la part de l installateur du propri taire o...

Страница 8: ...et ne retirez pas ses vis Aucune pi ce se trouvant l int rieur de l unit ne n cessite un entretien par l utilisateur 4 Seul un technicien form et qualifi est autoris entretenir et r parer cet quipeme...

Страница 9: ...ctor 5 If you use an extension cord with this system make sure that the total ampere rating on the products plugged into the extension cord does not exceed the extension cord ampere rating 6 To avoid...

Страница 10: ...rallonge avec ce syst me assurez vous que l amp rage total des produits branch s sur la rallonge ne d passe pas l amp rage nominal de celle ci 6 Pour viter tout risque de choc lectrique ou d endommage...

Страница 11: ...fety Cables and electrical cords should be routed in a manner that prevents safety hazards such as from tripping wire fraying overheating etc Ensure that nothing rests on the unit s cables or power co...

Страница 12: ......

Страница 13: ...matic notification You can define the events and location in the video of the image that can be detected with user customizable rules and positioning criteria Figure 1 trk 101 P Unit In addition to it...

Страница 14: ...el The power connection panel of the unit includes the following connections Item Description Grounding Terminal For connecting the unit to the protective ground earth according to local regulations a...

Страница 15: ...e in the second phase of the boot Requires resetting the unit Steady yellow Reset button was pressed for 5 15 seconds and entered Technician mode Requires resetting the unit Flashing yellow 500ms inte...

Страница 16: ...udes detection overlays and additional On Screen Display OSD information Typically connected to analog video equipment such as analog video displays or analog video recording device or digital video r...

Страница 17: ...e air is free to circulate around the unit The unit is protected from direct weather conditions for example sunlight rain dust and so on Caution To avoid damage from overheating or unit failure assure...

Страница 18: ...ount panel by inserting it through the holes as shown in Figure 6 Figure 6 Inserting Units into Rack Mount Panel 3 Fasten each unit using the nuts and washers removed in step 1 making sure to first pl...

Страница 19: ...Figure 3 trk 101 P Power Connection Panel 2 Attach a properly rated ground cable Make sure the ring spade terminal of the grounding cable is between the toothed washers Tighten the screw 3 Ensure that...

Страница 20: ...tic IP address rather than with DHCP This ensures that the IP address will not automatically change in the future and interfere with configurations and communication DNA has a simple user interface an...

Страница 21: ...file by clicking the icon The DNA application opens and the device is displayed in the window 3 Select the unit by right clicking on it Figure 7 DNA Discovery Window 4 If there are devices located on...

Страница 22: ...ox iii In the IP Address Gateway and Mask enter the respective LAN VLAN optional DNS values Figure 9 DNA Assign IP Static IP Dialog Box iv Click Update and wait for OK status to be displayed 7 Repeat...

Страница 23: ...e unit See Figure 4 trk 101 P Video Connection Panel page 4 To set the unit s video standard via its web interface 1 Enter the IP address of the unit in a browser The unit s Login window opens 2 Login...

Страница 24: ...ice ID Baud rate Parity Start bits Stop bits 6 Click Start PTZ Setup to run the wizard to configure PTZ settings For more information see section 5 3 1 2 1 1 in the HTML Edition Units User s Guide 7 W...

Страница 25: ...fore performing the following procedure Avertissement D branchez l alimentation de l unit avant d effectuer la proc dure suivante 1 Connect the leads from the external device dry contact output using...

Страница 26: ...LY OPEN or NORMALLY CLOSED configuration See Connecting Leads to a Spring Clamp Terminal Block page 19 The three terminal points for the relay output are located at the bottom left of the terminal blo...

Страница 27: ...Power Supply The unit can be reset by turning off the power and then turning it on again To reset a unit by removing the power supply 1 Turn off or disconnect the power to the unit 2 Turn on or reconn...

Страница 28: ...ion Manual 16 Appendix The appendix contains the following sections Technical Specifications page 17 Connecting Leads to a Spring Clamp Terminal Block page 19 Troubleshooting page 20 NO to NC Relay Co...

Страница 29: ...Frame Rate MPEG 4 SP Up to 25 30 fps PAL NTSC for all resolutions Rate Control Option CBR 128Kbps 4Mbps VBR Storage on the Edge 3 800 Mb 475MB event recording Network Ethernet IEEE 802 3 802 3U 1 x Et...

Страница 30: ...to 60 C 32 to 140 F Operating Humidity 5 to 95 non condensing Certifications Safety UL 60950 1 2007 IEC 60950 1 2005 Ed 2 A1 2009 A2 2013 EN 60950 1 2006 Ed 2 A11 2009 A1 2010 A12 2011 A2 2013 CAN CSA...

Страница 31: ...To connect a wire to the spring clamp terminal block 1 Strip the insulation form the end of each wire that is to be connected to the terminal block Approximately 1 cm 2 54 of wire should be exposed 2...

Страница 32: ...Connecting the Unit to the Network The IP address responds to a ping on the network from the workstation but does not show in the DNA application Disconnect the unit s Ethernet 10 100 port or turn th...

Страница 33: ...at the firewall analysis or blocking is not interfering with the video stream and supports the required ports and communication protocols Alarm inputs are not working Check the unit settings to confir...

Страница 34: ...er ON o Action Activate relay contact continuous ON Event 2 Triggering Event Detection Alarm according to your configuration o Action 1 Activate relay contact continuous OFF immediately o Action 2 Act...

Страница 35: ...0 Fax 44 0 1494 446928 info uk dvtel com INDIA AND SAARC GULF REGION DVTEL India Pvt Ltd 303 SSR Corporate Park Mathura Road Faridabad 121002 Haryana India Tel 91 129 431 5031 Fax 91 129 431 5033 info...

Страница 36: ...Call Us or Visit Our Showroom 1300 737 998 3 172 The Entrance Rd Erina...

Отзывы: