DVP LB.40WR Скачать руководство пользователя страница 18

 

Operating and Maintenance Instructions

 

 

LB.5WR – LC.25WR – LB.40WR – LB.60WR – LC.105WR

 

EN 

 

 

16 

www.dvp.it 

8702037 – 01/01/2011 – R.0 

 

 

TROUBLESHOOTING 

 

DAMAGE 

CAUSE 

REMEDY 

No voltage 

Provide power supply 

Thermal switch has tripped 

Identify reason and activate switch 

Room temperature is too low 

Restore room temperature to allowed range 

Motor winding damaged 

Contact Service Department 

(A) 

The pump does not run 

Suction of unpermitted substances 

(only LB.5WR) 

Contact Service Department 

Low oil in tank 

Top up oil 

Oil contaminated 

Change oil 

Intake filter obstructed (only LB.5WR) 

Replace the filter cartridge 

Pump gaskets damaged 

Contact Service Department 

(B) 

The pump cannot 

reach stated vacuum 

Discharge clogged 

Check couplings at outlet 

Air exhaust filter clogged 

Change the air exhaust filter 

Bearings damaged 

Contact Service Department 

Solid particles in the oil 

Change oil 

Vanes worn out 

Contact Service Department 

(C) 

Pump is noisy 

Motor coupling damaged  

(where present) 

Contact Service Department 

Oil is not the suitable type 

Change oil 

Poor room ventilation 

Install an auxiliary ventilator 

Motor fan broken 

Contact Service Department 

Wrong power supply to motor 

Check power supply 

 

(D) 

Pump runs hot 

Discharge clogged 

Check couplings at outlet 

High working pressure 

(close to atmospheric pressure) 

Check oil level frequently 

Pump runs hot 

See point “D” 

 

(E) 

High oil consumption 

Air exhaust filter clogged 

Change the air exhaust filter 

(F) 

Pump does not 

maintain vacuum after 

power-off 

Check valve damage 

Contact Service Department 

Tank screws, oil drain valve or plugs loosened 

Tighten screws, valve or plugs 

Tank gaskets damaged 

Contact Service Department 

(G) 

Pump leaks oil 

Oil sight glass not tightened 

Tighten the oil sight glass 

 

Содержание LB.40WR

Страница 1: ...TECHNOLOGY OPERATING AND MAINT ENANCE INSTRUCTIONS Translation of the original instructions VACUUM PUMPS WITH RECIRCULATING LUBRICATION SYSTEM LB 5WR LC 25WR LB 40WR LB 60WR LC 105WR www dvp it info...

Страница 2: ...entele to reach its objectives For this reason our customers are the focus of our attention and we promote the sending of suggestions and or proposals for improvements that could be applied to our pro...

Страница 3: ...AND HANDLING 9 4 4 STORAGE 9 4 5 ENVIRONMENTAL CONDITIONS 9 4 6 PUMP INSTALLATION 10 4 7 MOTOR INSTALLATION ONLY LC 105WR 10 4 8 USER SYSTEM 10 4 9 CONNECTION 10 4 9 1 ASSEMBLING THE INTAKE FILTER ON...

Страница 4: ...model and serial number year of manufacture date of purchase detail information regarding problems verified 1 3 METHOD OF CONSULTATION For improved understanding of the information provided in this ma...

Страница 5: ...other identification plaques D V P Vacuum Technology S r l disclaims any liability for damage to persons or property resulting from improper use of the pump from tampering with its safety apparatus o...

Страница 6: ...mps are designed specifically to work with clean air and inert gases in atmospheres with a high amount of water vapour Any other use is prohibited The Manufacturer is not liable for any damage to pers...

Страница 7: ...capacity m h 5 6 Final pressure Abs mbar hPa 10 Max inlet pressure for water vapour mbar hPa 30 Max water vapour pumping rate Kg h 0 11 Motor power kW 1 3 0 25 0 37 0 25 0 45 Nominal r p m n min 1400...

Страница 8: ...2 Max inlet pressure for water vapour mbar hPa 50 Max water vapour pumping rate Kg h 0 9 Motor power kW 1 3 0 75 0 75 0 90 0 90 Nominal r p m n min 1400 1700 Noise level UNI EN ISO 2151 K 3dB dB A 62...

Страница 9: ...x inlet pressure for water vapour mbar hPa 40 50 Max water vapour pumping rate Kg h 1 2 2 1 Motor power kW 3 1 1 1 35 1 5 1 8 Nominal r p m n min 1400 1700 1400 1700 Noise level UNI EN ISO 2151 K 3dB...

Страница 10: ...mbar hPa 2 Max inlet pressure for water vapour mbar hPa 40 Max water vapour pumping rate Kg h 2 9 Motor power kW 3 2 2 2 7 Nominal r p m n min 1400 1700 Noise level UNI EN ISO 2151 K 3dB dB A 68 70 W...

Страница 11: ...e with local regulations Do not burn or disperse package components in the environment 4 3 TRANSPORT AND HANDLING HAZARD All transportation lifting and handling operation must be performed by qualifie...

Страница 12: ...to install any type of electric or hydraulic motor that has the features described in the table of technical data with flange and shaft corresponding to M100 4 B5 size as per standard IEC 72 WARNING...

Страница 13: ...uate for the power absorbed by the pump absorption values are shown on the pump motor rating plate taking into account the environmental conditions of operation HAZARD Always ground the pump Always in...

Страница 14: ...ime with the suction inlet completely open WARNING It is advisable not to start the pump more than 12 times per hour to avoid excessive energy consumption and damage to the pump especially for model L...

Страница 15: ...n and or repair of any kind except for those listed in this manual Only trained or authorised personnel have the necessary expertise to perform tasks with the technique appropriate for intervention HA...

Страница 16: ...e for about 10 minutes first so oil will become thinner stop the pump and disconnect it from the mains undo the oil filler plug get a container large enough to hold all oil and open the oil drainage v...

Страница 17: ...l viewer 5503002 Intake filter cartridge 1801019 D V P Vacuum Technology S r l disclaims all responsibility for any deterioration of pump performance or for damages caused due to use of non original s...

Страница 18: ...e the air exhaust filter Bearings damaged Contact Service Department Solid particles in the oil Change oil Vanes worn out Contact Service Department C Pump is noisy Motor coupling damaged where presen...

Страница 19: ...appear to be faulty due to negligence and or carelessness during use failure to observe the equipment operating instructions lack of maintenance incorrect installation and or maintenance maintenance c...

Страница 20: ...D V P Vacuum Technology srl Via Rubizzano 627 40018 San Pietro in Casale BO Italy Tel 39 051 18897101 Fax 39 051 18897170 Email info dvp it Cod 8702037 01 01 2011 R 0 EN...

Отзывы: