![DVP LB.40WR Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/dvp/lb-40wr/lb-40wr_operating-and-maintenance-instructions-manual_2544115010.webp)
Operating and Maintenance Instructions
LB.5WR – LC.25WR – LB.40WR – LB.60WR – LC.105WR
EN
8
www.dvp.it
8702037 – 01/01/2011 – R.0
3.3.4
Model: LC.105WR
Attachment
point
Motor
rating plate
Intake
Motor fan
guard
Oil
viewer
Attachment
point
Terminal
board
Air
outlet
Oil sight
glass
Oil filler
plug
Oil drainage
valve
Information
plate
Level
switch
Only on "FKM" versions
LC.15WR
TECHNICAL SPECIFICATIONS
50 Hz
60 Hz
Inlet capacity
m³/h
105
125
Final pressure (Abs.)
mbar - hPa
2
Max inlet pressure for water vapour
mbar - hPa
40
Max water vapour pumping rate
Kg/h
2,9
Motor power
kW (3
~
)
2,2
2,7
Nominal r.p.m.
n/min
1400
1700
Noise level (UNI EN ISO 2151) (K 3dB)
dB(A)
68
70
Weight
kg (3
~
)
70,0
Type of oil
cod. DVP
SW100 (BV100)
Oil quantity
Min÷Max dm³
2 ÷ 3
Pump Intake / Outlet
“G
1-1/2 / 1-1/4
Continuous-duty working renge (Abs.)
mbar - hPa
400 ÷ 2
Operating temperature (room temp. 20°C)
°C
75 ÷ 80
80 ÷ 85
Required room temp. for place of installation
°C
12 ÷ 40
Ambient temperature for storage/transport
°C
-20 ÷ 50
MAX humidity / altitude
80% / 1000m a.s.l. *
(*) Please contact the Manufacturer if environmental conditions are different from those prescribed.