When you select the tab
“Read”
you can read individual parameter from the receiver - control unit NBB.
You can change them and
“Write”
them back to the control unit. You can match the control unit (receiver)
with a new remote controller, change parameters of the hydraulic pump and read status of operating hours
Functions
Default values:
Recommended range of values:
Zero Offset
127
115-135
Maximum Angle
80
0-80
Minimum Power Offset
700
600-800
Zero Range
4
2-5
Contra Signal
255
255
Possible adjustments:
Zero Offset
-
To set an offset to the middle (neutral) position of the hydraulic servomotor
Maximum Angle
-
To set (limit) the maximum angle of the hydraulic servomotor (speed of the mower)