background image

10

CDW247001

30004577

MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without 
notice.

CDW247001 Wood Stove

 

Item No. 

Description 

Qty. 

Part No.

 

1. 

Door Assembly 

90000082

 

2 & 3. 

Glass and Gasket 

S31117

 

3. 

1/8” Glass Gasket 

4.0’ 

S15001

 

4. 

5/8” Door Gasket 

4.5’ 

S15011

 

5. 

Spring Handle 

90000069

 

6. 

Air Control Spring Handle 

90000070

 

7. 

Glass Clip 

S37034

 

8. 

Screw 

S11086

 

9. 

Hinge Pin 

S11005

 

10. 

Push Nut 

S11090

 

11. 

Firebrick Lt. 9” x 4

⁷⁄₁₆

” x 1

¹⁄₄

” 

10 

S16040

 

12. 

Firebrick Lt 6

¹⁄₂

” x 4

⁷⁄₁₆

” x 1

¹⁄₄

” 

S16249

1

2

3

4

5

7

8

9

10

7

7

8

8

4577 
CDW247001 parts
10/08

11

12

12

12

12

12

12

12

12

11

11

11

11

11

11

11

8

Содержание DutchWest CDW247001

Страница 1: ...EMENTS IN YOUR AREA This stove is listed by OMNI Test Laboratories of Port land Oregon to meet UL1482 for the US and ULC 627 for Canada Do Not Discard This Manual Retain for Future Use 6 Flue required...

Страница 2: ...r indicates excessive draft Inad equate draft may cause back puf ng into the room and plugging of the chimney and or cause the appliance to leak smoke into the room through appliance and chim ney conn...

Страница 3: ...unsafe installation 6 Flue Required A B C D E F G Single wall 10 10 10 19 11 19 54 Connector 267 267 267 483 292 483 1372 Double wall 2 5 2 10 5 10 54 Connector 84 127 64 267 140 254 1372 Baf e Assem...

Страница 4: ...METHODS OF INSTALLATION 1 This appliance requires a masonry or pre manufac tured chimney listed to ULC S629 Canada and UL 103HT US sized correctly 2 If a masonry chimney is used it is advisable to ha...

Страница 5: ...m The solution would be to reduce the area by relining it with an approved chimney liner or replacing the chimney Regulations specify the chimney must extend 2 610 mm above a 10 3 m radius of the top...

Страница 6: ...tly ignited While a basic rule of thumb is closed low 1 2 way medium and fully open high refer to the Inlet Air Control Settings chart 9 When refueling adjust air control to the fully open position Wh...

Страница 7: ...wood to achieve the charcoal stage faster and burns wood vapors which might otherwise be depos ited within the system WARNING Things to remember in case of chim ney re 1 Close draft control 2 Call the...

Страница 8: ...ry seasoned wood will deposit creosote on the inside of your stove and along the inside of your chimney 3 What does dry seasoned wood mean and what is considered hardwood Wood that has been dried for...

Страница 9: ...t fteen to forty minutes being careful not to over re If any part of the chimney or parts of the stove start to glow you are over r ing the stove Where possible install a tempera ture gauge on the chi...

Страница 10: ...sembly 1 90000082 2 3 Glass and Gasket 1 S31117 3 1 8 Glass Gasket 4 0 S15001 4 5 8 Door Gasket 4 5 S15011 5 Spring Handle 1 90000069 6 Air Control Spring Handle 1 90000070 7 Glass Clip 6 S37034 8 Scr...

Страница 11: ...SC supplier or MHSC Customer Service Department 10 MHSC will not be responsible for Down drafts or spillage caused by environmental conditions such as near by trees buildings rooftops hills mountains...

Страница 12: ...n pour les po les bois x es par l agence Am ricaine de protection de l environnement Dans des conditions sp cifiques ce po le d gage entre 11 492 et 18 920 BTU l heure AVIS DE S CURIT Si le po le n es...

Страница 13: ...E DES INCENDIES 10 NE TRAFIQUEZ PAS la commande d admission d air au del de son r glage normal Fonctionnement pr caution Pourquoi un conduit d vacuation de 6 po 152 mm Le tirage est le d placement de...

Страница 14: ...ureau local d inspection des b timents les distances de d gagement minimales respecter 4 Installez des briques r fractaires Fig 2 5 Installez le tuyau fum e L INT RIEUR du collier de la chemin e sur l...

Страница 15: ...er des refoulements de fum e 7 Il n est pas n cessaire d avoir de r gulateur de tirage Retirez la plaque de r gulation du tirage install dans la chemin e ou fixez la en position OUVERTE Maisons mobile...

Страница 16: ...du sol de l emplacement du po le et de l installation de l admission d air de combus tion provenant de l ext rieur Mise en garde L int grit structurale du plancher de la maison mobile des murs du plaf...

Страница 17: ...pi 610 mm de plus que tout autre objet qui se trouve dans un rayon de 10 pi 3 0 m du dessus de la chemi n e endroit bien ventil Et le bois doit tre gard distance de tout combustible Ne br lez pas du...

Страница 18: ...s que l appareil est bien refroidi 2 Enlevez les vis et la bordure de fixation voir sch ma des pi ces 3 Retirez la vitre 4 Enlevez le vieux joint et nettoyez la vitre 5 Installez le joint neuf en comm...

Страница 19: ...ez la porte et laissez s cher la colle durant trois quatre heures avant d utiliser l appareil 3 NE BR LEZ QUE DU BOIS SEC vitez le bois vert Le bois sec doit avoir s ch pendant au moins un an 4 Un pet...

Страница 20: ...s la commande d admission d air est r gl e un niveau bas plus la combustion de votre bois durera longtemps 2 Quel est le meilleur type de bois qu on peut utiliser dans le po le Vous devriez utiliser d...

Страница 21: ...te poru laisser entrer l air dans la maison b Conditions environnementales Les grands arbres les d pressions comme une vall e les grands di ces ou structures adjacents votre maison et l intensit du ve...

Страница 22: ...on d air 1 90000070 7 Ferrure pour la vitre 6 S37018 8 Vis 6 S11086 9 Hinge Pin 2 S11005 10 Push Nut 2 S11090 11 Brique 9 x 4 x 1 10 S16040 12 Brique 6 x 4 x 1 1 S16249 MHSC se r serve le droit de fai...

Страница 23: ...nes ou une conception de chemin e inad quate de la ventilation inad quate des d volements excessifs ou de la pression d air n gative caus s par des syst mes m caniques tels que les foyers les s cheuse...

Страница 24: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: