background image

6

CDW247001

30004577

hotter surfaces of the stove, and is caused by the heat 
radiating through the paint. It is also expected that shiny 
spots caused by friction from the packaging materials, 
will disappear during the curing of the stove.

SO:

1.  Remember to ventilate well.
2.  Allow the stove to cure before burning for long peri-

ods at high temperatures.

3.  Flat spots on the painted surfaces are normal.
4.  Shiny spots on the paint surface before burning is 

normal.

5.  Call your dealer if you have any questions.

Building a Fire

Never use gasoline, gasoline-type latern fuel, ker-
osene,  charcoal  lighter  fluid  or  similar  liquids  to 
start or ‘freshen up’ a fire in this heater. Keep all 
such liquids well away from the heater while it is 
in use.

Inlet Air Control Settings

 

Desired 

 

Inlet 

 

**Approx. 

 

Burn Setting 

Air Setting 

BTU Output

 

Low 

Closed Fully 

11,492

  Med / Low 

1/4 Open 

11,721

  Med / High 

3/4 Open 

15,501

 

High 

Fully Open 

18,920

1.  Open inlet air control fully.
2.  Place a small amount of crumpled paper in the 

stove.

3.  Cover the paper with a generous amount of kindling 

in a teepee fashion and a few small pieces of wood.

4.  Ignite the paper and close door. If fire dies down 

substantially, open door slightly.

5.  Add larger pieces of wood as the fire progresses be-

ing careful not to overload. Do not fill firebox beyond 
firebrick area. An ideal coal bed of 1” to 2” should be 
established to achieve optimum performance.

6.  This unit is designed to function most effectively 

when air is allowed to circulate to all areas of the 
firebox. An ideal means of achieving this is to rake a 
slight (1” to 2” wide) trough in the center of the coal 
bed from front to back prior to loading the fuel.

7.  Once fuel has been loaded, close the door and open 

air inlet control fully until fire is well established (ap-
prox. 10 minutes) being careful not to overfire.

8.  Readjust air inlet control to desired burn rate. If 

excessive smoke fills firebox, open air inlet control 
slightly until flames resume and wood is sufficiently 
ignited. While a basic rule of thumb is “closed-low”, 
“1/2 way - medium” and “fully open-high”, refer to the 
Inlet Air Control Settings chart.

9.  When refueling, adjust air control to the fully open 

position. When fire brightens, slowly and carefully 
open the door. This procedure will prevent gases 
from igniting causing smoke and flame spillage.

10.Add fuel being careful not to overload.

Glass Care

The following use and safety tips should be observed.
1.  Inspect the glass regularly for cracks and breaks. If 

you detect a crack or break, extinguish the fire im-
mediately and contact your dealer for replacement.

2.  Do not slam door or otherwise impact the glass. 

When closing doors, make sure that logs or other 
objects do not protrude and impact the glass.

3.  Do not clean the glass with materials which may 

scratch (or otherwise damage) the glass. Scratches 
on the glass can develop into cracks or breaks.

4.  Never attempt to clean the glass while unit is hot. If 

the deposit is not very heavy, normal glass clean-
ers are adequate with a plain, nonabrasive scouring 
pad. Heavier deposits may be removed with the use 
of a readily available oven cleaner.

5.  Never put substances which can ignite explosively 

in the unit since even small explosions in confined 
areas can blow out the glass.

6.  This unit has an airwash system, designed to reduce 

deposits on glass.

Replace glass only with high temperature Robax 
Pyroceram of the proper size and thickness.

Gasket Replacement

After extensive use, the sealing material which provides 
glass and door seal may need to be replaced if it fails 
to sustain its resilience. Inspect glass and door seal pe-
riodically to ensure for proper seal. If gaskets become 
frayed or worn, replace immediately.
Contact your dealer for approved replacement parts.
The following steps should be followed for glass gasket 
replacement:
1.  Ensure appliance is not in operation and has thor-

oughly cooled.

2.  Remove screw and glass clip.
3.  Lift glass out from glass clip.
4.  Remove old gasket and clean glass.
5.  Replace new gasket starting at the bottom of glass 

working along edges, being sure to center gasket 
channel on glass. 

6.  Trim to length and butt ends together.

Содержание DutchWest CDW247001

Страница 1: ...EMENTS IN YOUR AREA This stove is listed by OMNI Test Laboratories of Port land Oregon to meet UL1482 for the US and ULC 627 for Canada Do Not Discard This Manual Retain for Future Use 6 Flue required...

Страница 2: ...r indicates excessive draft Inad equate draft may cause back puf ng into the room and plugging of the chimney and or cause the appliance to leak smoke into the room through appliance and chim ney conn...

Страница 3: ...unsafe installation 6 Flue Required A B C D E F G Single wall 10 10 10 19 11 19 54 Connector 267 267 267 483 292 483 1372 Double wall 2 5 2 10 5 10 54 Connector 84 127 64 267 140 254 1372 Baf e Assem...

Страница 4: ...METHODS OF INSTALLATION 1 This appliance requires a masonry or pre manufac tured chimney listed to ULC S629 Canada and UL 103HT US sized correctly 2 If a masonry chimney is used it is advisable to ha...

Страница 5: ...m The solution would be to reduce the area by relining it with an approved chimney liner or replacing the chimney Regulations specify the chimney must extend 2 610 mm above a 10 3 m radius of the top...

Страница 6: ...tly ignited While a basic rule of thumb is closed low 1 2 way medium and fully open high refer to the Inlet Air Control Settings chart 9 When refueling adjust air control to the fully open position Wh...

Страница 7: ...wood to achieve the charcoal stage faster and burns wood vapors which might otherwise be depos ited within the system WARNING Things to remember in case of chim ney re 1 Close draft control 2 Call the...

Страница 8: ...ry seasoned wood will deposit creosote on the inside of your stove and along the inside of your chimney 3 What does dry seasoned wood mean and what is considered hardwood Wood that has been dried for...

Страница 9: ...t fteen to forty minutes being careful not to over re If any part of the chimney or parts of the stove start to glow you are over r ing the stove Where possible install a tempera ture gauge on the chi...

Страница 10: ...sembly 1 90000082 2 3 Glass and Gasket 1 S31117 3 1 8 Glass Gasket 4 0 S15001 4 5 8 Door Gasket 4 5 S15011 5 Spring Handle 1 90000069 6 Air Control Spring Handle 1 90000070 7 Glass Clip 6 S37034 8 Scr...

Страница 11: ...SC supplier or MHSC Customer Service Department 10 MHSC will not be responsible for Down drafts or spillage caused by environmental conditions such as near by trees buildings rooftops hills mountains...

Страница 12: ...n pour les po les bois x es par l agence Am ricaine de protection de l environnement Dans des conditions sp cifiques ce po le d gage entre 11 492 et 18 920 BTU l heure AVIS DE S CURIT Si le po le n es...

Страница 13: ...E DES INCENDIES 10 NE TRAFIQUEZ PAS la commande d admission d air au del de son r glage normal Fonctionnement pr caution Pourquoi un conduit d vacuation de 6 po 152 mm Le tirage est le d placement de...

Страница 14: ...ureau local d inspection des b timents les distances de d gagement minimales respecter 4 Installez des briques r fractaires Fig 2 5 Installez le tuyau fum e L INT RIEUR du collier de la chemin e sur l...

Страница 15: ...er des refoulements de fum e 7 Il n est pas n cessaire d avoir de r gulateur de tirage Retirez la plaque de r gulation du tirage install dans la chemin e ou fixez la en position OUVERTE Maisons mobile...

Страница 16: ...du sol de l emplacement du po le et de l installation de l admission d air de combus tion provenant de l ext rieur Mise en garde L int grit structurale du plancher de la maison mobile des murs du plaf...

Страница 17: ...pi 610 mm de plus que tout autre objet qui se trouve dans un rayon de 10 pi 3 0 m du dessus de la chemi n e endroit bien ventil Et le bois doit tre gard distance de tout combustible Ne br lez pas du...

Страница 18: ...s que l appareil est bien refroidi 2 Enlevez les vis et la bordure de fixation voir sch ma des pi ces 3 Retirez la vitre 4 Enlevez le vieux joint et nettoyez la vitre 5 Installez le joint neuf en comm...

Страница 19: ...ez la porte et laissez s cher la colle durant trois quatre heures avant d utiliser l appareil 3 NE BR LEZ QUE DU BOIS SEC vitez le bois vert Le bois sec doit avoir s ch pendant au moins un an 4 Un pet...

Страница 20: ...s la commande d admission d air est r gl e un niveau bas plus la combustion de votre bois durera longtemps 2 Quel est le meilleur type de bois qu on peut utiliser dans le po le Vous devriez utiliser d...

Страница 21: ...te poru laisser entrer l air dans la maison b Conditions environnementales Les grands arbres les d pressions comme une vall e les grands di ces ou structures adjacents votre maison et l intensit du ve...

Страница 22: ...on d air 1 90000070 7 Ferrure pour la vitre 6 S37018 8 Vis 6 S11086 9 Hinge Pin 2 S11005 10 Push Nut 2 S11090 11 Brique 9 x 4 x 1 10 S16040 12 Brique 6 x 4 x 1 1 S16249 MHSC se r serve le droit de fai...

Страница 23: ...nes ou une conception de chemin e inad quate de la ventilation inad quate des d volements excessifs ou de la pression d air n gative caus s par des syst mes m caniques tels que les foyers les s cheuse...

Страница 24: ...MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com...

Отзывы: