background image

8

Customer Service Helpline 1.800.568.3949 dustlesstools.com

USAGE 

cont

CHANGING WUNDERBAGS

1. Disconnect the vacuum from outlet.
2. Remove intermediate.

3. Seal and remove full WunderBag. Note: To 

avoid back strain, do not lift a full bag.

4. Install new WunderBag. (Refer to 

WunderBag Installation)

STORAGE

1. Disconnect from outlet
2. Empty barrel.
3. Rinse barrel thoroughly and wipe out.
4. Store hose and attachments.

EXTENSION CORDS

When using the appliance at a distance where 

an extension cord becomes necessary, a 

3-conductor grounding cord of adequate 

size must be used for safety, and to prevent 

loss of power and overheating. Use the table 

that follows to determine A.W.G. wire size 

required. To determine ampere rating of your 

vacuum, refer to nameplate located on rear of 

motor cover. Before using appliance, inspect 

power cord for loose or exposed wires and 

damaged insulation. Make any needed repairs 

or replacements before using your appliance. 

Use only three-wire outdoor extension cords 

which have three-prong grounding-type plugs 

and three-pole receptacles which accept the 

extension cords plug. When vacuuming liquids, 

be sure the extension cord connection does 

not come in contact with the liquid.  

VOLTS

TOTAL LENGTH OF EXTENSION 

CORD IN FEET

120V

25

50

100

150

Ampere Rating

 

More 

Not More

 Than 

Than

AWG

0 - 6

18

16

16

14

6 - 10

18

16

14

12

10 - 12

16

16

14

12

12 - 16

14

12

Not  

Recommended

NOTE: STATIC SHOCKS ARE COMMON 

IN DRY AREAS OR WHEN THE RELATIVE 

HUMIDITY OF THE AIR IS LOW. THIS IS ONLY 

TEMPORARY AND DOES NOT AFFECT 

THE USE OF THE APPLIANCE. TO REDUCE 

THE FREQUENCY OF STATIC SHOCKS IN 

YOUR HOME, THE BEST REMEDY IS TO ADD 

MOISTURE TO THE AIR WITH CONSOLE OR 

INSTALLED HUMIDIFIER.

Содержание DuctlessVac D1603

Страница 1: ...OWNERS MANUAL D16 Series dustlesstools com PATENT NO 5954863 5704956 This appliance is intended for commercial and household use ...

Страница 2: ...nplug from outlet when not in use and before servicing ELECTRICAL SAFETY cont Electrical components are not user serviceable Refer all service to a qualified repair technician Do not handle plug or operate vacuum with wet hands PERSONAL SAFETY Do not allow to be used as a toy Close attention is necessary when used by or near children Do not change filters clean the unit or empty the barrel until t...

Страница 3: ...ical Code C22 1 B C Adapter A Grounded Plug TOOL USE AND CARE Always check the filters before each use Do not use without a dust collection bag and filters in place Do not use with damaged cord or plug If appliance is not working as it should has been dropped damaged left outdoors or dropped into water return it to a service center Do not pull or carry by the cord use cord as a handle close a door...

Страница 4: ...AL WET DRY VAC Crevice Tool Floor Tool Lid Barrel Hose WunderBag 10 Clamp 7 Clamp Inner Filter Outer Filter WunderBag Filter Cover HEPA Filter 10 Clamp WunderBag 10 Clamp 7 Clamp Inner Filter Outer Filter Shaker Basket Shaker Basket Extension Wands Crevice Tool Floor Tool Lid Barrel Hose Extension Wands Crevice Tool Floor Tool Lid Barrel Hose HEPA Filter Support Filter Cleaning Weight ...

Страница 5: ...16 GAL WET DRY VAC Dustie HEPA Floor Tool Adapter ChipBuddie 6 Hose 32 Clamp Zip Tie D1608 RENOVATE RIGHT EPA HEPA KIT ChipBuddie DustBuddie 18 Hose HEPA Floor Tool Adapter HEPA Floor Tool Adapter WunderBag Filter Cover HEPA Filter 10 Clamp Extension Wands Crevice Tool Floor Tool Lid Barrel Hose HEPA Filter Support Filter Cleaning Weight IN THE BOX cont ...

Страница 6: ...el 2 Reach inside the port and with your fingers press cardboard tight and secure around port WET PICKUP 1 Vacuum should be emptied of any dry waste Filters can remain in place Note Should filters become wet dry both filters thoroughly before continued use 2 Connect hose and desired attachment 3 After use or when barrel is full turn off vacuum and disconnect from outlet Note When barrel is full th...

Страница 7: ...rs or Filter Installation 4 After use or when barrel is full turn off vacuum and disconnect from outlet 5 Remove intermediate from barrel 6 Empty barrel and or remove WunderBag Note To avoid back strain do not lift a full barrel bag CLEAN FILTERS HEPA WET DRY 1 Turn the vacuum off and wait 5 seconds after motor comes to a stop Repeat 5 times This allows weight to expand filter cover and release du...

Страница 8: ...ameplate located on rear of motor cover Before using appliance inspect power cord for loose or exposed wires and damaged insulation Make any needed repairs or replacements before using your appliance Use only three wire outdoor extension cords which have three prong grounding type plugs and three pole receptacles which accept the extension cords plug When vacuuming liquids be sure the extension co...

Страница 9: ... 3 Place the outer filter over the shaker basket and around the raised lip on the lid lip is 1 from edge of the lid attach with the 10 hose clamp Tighten the clamp with a screw driver FILTER INSTALLATION REGULAR WET DRY 1 Place the HEPA filter over the crosspiece stud and slide on the washer Screw on the wing nut to compress the washer and filter seal 2 Place the HEPA filter cover support on the H...

Страница 10: ...LATION HEPA WET DRY cont Adjustments servicing and inspection work and inspection intervals specified in these Operating Instructions as well as any information on the replacement of parts and systems of the vacuum must be undertaken and complied with These activities can only be undertaken by qualified personnel Make sure that electrical components used for replacement comply with the original pa...

Страница 11: ...ls com QUESTION ANSWER Why is the vacuum blowing dust Check filter s for holes and that they are securely in place WunderBag may not be securely in place Why have I lost suction The drain cap may be open Check and clear any obstruction in the hose or attachments Filters may need to be cleaned replaced Agitator rod cover brass plug may need tightening WunderBag may be full and need to be replaced H...

Страница 12: ... 5 Dustie Model D1854 5 DustBuddie Model D1835 DustBuddie for 7 1 4 Worm Drive Hypoid Circular Saws Model D4000 1 3 8 BitBuddie Model D1900 7 CutBuddie Model D1750 HEPA Back Pack Model 15505 OM007_0117 7 DustBuddie Model D5850 7 ChipBuddie Model D1750 SawBuddie Model D2415 Drywall Sander Model 50001 ...

Отзывы: