background image

3

NOTICE

         

DANGER

         

WARNING

         

CAUTION

READING THIS MANUAL

Save these instructions & keep track of your product’s serial#

This manual contains important safety and operating information and instructions based on information 

known by Canature. Canature has no knowledge of and makes no representations or warranties respecting 

the product’s design, manufacturing, testing, packaging and inspecting. 
Read all information and instructions and consider all information and follow all instructions when using this 

product. Failure to consider this information and follow these instructions may result in property damage, 

injury and/or death.

Throughout this manual, certain conventions are used, including;

 

Hazard symbols

 

– For your own safety, please pay strict attention! Examples include:

 

Hazard signals

 – indicate the degree of harm that will or may occur, look like those below.

Temperature

White lettering with red background & safety alert symbol.

Black lettering with orange background & safety alert symbol.

Black lettering with yellow background & safety alert symbol.

White lettering with bright blue background.

Electrical

Motor Restart

 

Warranty exclusions 

 – these also require strict attention in order to protect your wise investment in water  

 security.

 

Notes 

 – help you take 

full advantage of the system 

and are used to emphasize 

installation, operation, or 

maintenance information 

which is important but does 

not present a hazard.

NOTE

Information being  

emphasized.

INTRODUCTION

 

This pump has been carefully packaged, inspected, and tested to ensure safe operation and delivery. Before installing the 

pump, check to see if any damage has occurred from rough handling.
Notify the dealer you purchased the pump from with the details of any damage.
This sewage pump is suitable for pumping sewage, effluent, groundwater, and other non explosive, non-corrosive liquids with 

up to 51 mm [2”] solids. The pump includes a wide angle float switch that turns the pump on and off as the fluid level rises 

and falls.
The manufacturer reserves the right to make product improvements which may deviate from the specifications and  

descriptions stated herein, without obligation to change previously manufactured products or to note the change.

Содержание TITAN DSBF300

Страница 1: ...IN CATASTROPHICEVENTSORIN POWERFAILURES MONITORTHIS PRODUCTCLOSELY CanatureWaterGroup Canada Inc Canature did not design or manufacture this product Canature has no knowledge of and makes no representations or warranties respecting the product s design manufacturing testing packaging or inspecting Canature has disclosed all known risks associated with the product within this manual but cannot disc...

Страница 2: ... 3 4 of less solids 5 Piping for Sewage Applications 51 mm 2 or less solids DSBW300 5 CheckValves Air Locking 5 Basin Cover Vent 5 Electrical Installation 6 AutomaticThermal Overload Protection 6 Liquid Level Control Operation 6 Optional Alarm 6 Maintenance 7 Cleaning the Pump 8 Troubleshooting Checklist 9 Guarantee 10 Additional Limitations 11 Notice to Consumer 11 ...

Страница 3: ...ering with yellow background safety alert symbol White lettering with bright blue background Electrical Motor Restart Warranty exclusions these also require strict attention in order to protect your wise investment in water security Notes help you take full advantage of the system and are used to emphasize installation operation or maintenance information which is important but does not present a ...

Страница 4: ...les 2 We recommend that a separate circuit be led from the home electrical distribution panel and properly protected with a circuit breaker We also recommend that a ground fault circuit GFI be used Consult a licensed electrician for all wiring 3 Do not stand in water when connecting or disconnecting the power cord from the outlet 4 This product should be connected to a three prong grounded outlet ...

Страница 5: ...hreaded discharge is required secure adapter to volute bottom casing with ABS cement If a threaded discharge is NOT necessary cement pipe directly to volute CheckValves Air Locking Check local codes to determine if a check valve is recommended Air locking may occur if the sump empties after extended periods of dry weather When wet weather returns and the sump begins to refill air may become trappe...

Страница 6: ...ration will resume when the motor cools enough to close the overload switch Liquid Level Control Operation A float switch is used for automatic operation to turn pump on and off Adjust liquid level control to suit the following conditions 1 Pump should not operate for extended periods of time while motor housing is in air Otherwise thermal protection will turn motor off 2 PumpMUSTNOToperateforanyl...

Страница 7: ...ssional assistance if the pump does NOT activate Maintenance should take place annually and when the home is sold Whentestingthepump nooneshouldeverreachintothepit Thefloatcanbereachedandmanipulatedwithahousehold item such as a golf club with a rubber handle or anything else non conductive laying around Refer to troubleshooting checklist if pump does not operate properly Do NOT disassemble the mot...

Страница 8: ...lockwise to release 8 Remove debris from around the shaft and impeller then clean impeller and inner volute using water Do NOT use strong solvents paint thinner gasoline which may damage the plastic 9 Reattach volute and reassemble Alterations to the power cord voids the warranty Do NOT use this pump to pump liquids water in excess of 37 8 C 100 F Disassembly for Cleaning Item Description 1 302701...

Страница 9: ...ating and overloading 2 Pump will NOT stop running Liquid level control caught on basin sides or pump Free float and reinstall it so that its motion is unobstructed 3 Motor runs but does not pump sufficient or any water Pump is air locked Run pump through several quick on off cycles by plugging and unplugging pump cord Detach from piggyback plug first Impeller volute and or suction opening is plug...

Страница 10: ...ranties to the extent permitted by law For clarity where exclusion is not permitted by law those express or implied warranties are not excluded by this warranty This warranty is subject to the following conditions and limitations 1 A bill of sale verifying the purchase and purchase date must be provided 2 This warranty will NOT apply to any product or part thereof which is worn or broken or which ...

Страница 11: ...ve material 5 Scale or corrosion buildup due to excessive chemical content 6 Any modification of the original equipment We will NOT be responsible for loss damage or labor cost due to the interruption of service caused by defective parts Neither will we accept charges incurred by others without our prior written approval This warranty is void if our inspection reveals the product was used in a man...