Operating manual part II
II-12
© 2010 Dürkopp Adler AG
L
C
P
Min
Max
Preset Unity
Description
Turning Back
t
12 00 0
1
0
-
Turning back
0 = No;
1 = Yes
t
12 01 10
180
10
°
Moving angle of rotation
t
12 02 10
255
20
ms
Waiting time up to the turning back
Needle cooling
t
13 00 0
1
0
-
Mode of the needle cooling
0 = Normal needle cooling;
1 = Needle cooling depending on speed
t
13 01 0,0
9,999
2,500
s
Switch-off delay of needle cooling
t
13 02 100
9999
!!!!
rpm
Speed for activate the needle cooling
Roller
t
14 00 0
3
0
-
Mode for lifting the roller
0 = No lifting;
1 = Lifting with sewing foot;
2 = Lifting with bartack;
3 = Lifting with bartack and sewing foot
t
14 01 0
1
0
-
Lifting roller when enabling high lift for walking foot.
0 = No;
1 = Yes
t
14 02 0
1
0
-
Stitch counting after sewing foot lifting till roller remains
lowered.
0 = No;
1 = Yes
t
14 03 0
255
0
Stitches
Number of stitches till lower the roller
Miscellaneous of the control
t
51 00 -
-
-
-
Showing software version
t
51 01 -
-
-
-
Showing control serial number
t
51 02 -
-
-
-
Showing machine serial number
t
51 03 -
-
-
-
Showing production date
t
51 04 -
-
-
-
Showing machine class and –sub class
t
51 10 0
4
-
-
Load of parameters
0 = Nothing;
1 = Sewing data of the there dongle;
2 = Sewing data of the backup area;
3 = Seam ways of the there Dongle
4 = Master reset
t
51 11 0
3
-
-
Store of parameters
0 = Nothing;
1 = Sewing data on the there dongle;
2 = Sewing data to the backup area;
3 = Seam ways on the there Dongle