Operating manual part II
II-4
© 2010 Dürkopp Adler AG
PART II
1
Parameter
The parameter overview is help a sought-after parameter for finding fast and changing. The construction of the list
has already been explained in the list using structure.
There are parameters, which can be found in the technicians' and developers' level both different consequences,
however, have. All settings in the developers' level aren't accessible for using staff and service technicians but are
adjusted by the software developers to the certain hardware once.
1.1
Parameter of class 271
class:
271
t 08 04
set of parameters:
271-140342-01
for sub-class:
271-140342-01
1.1.1 Operator-level
L
C
P
Min
Max
Preset Unity
Description
Bobbin thread counter and bobbin thread monitor
o
06 00 0
4
0
-
Activate the bobbin thread counter
0 = off;
1 = Bobbin thread counter A;
2 = Bobbin thread counter B;
3 = Bobbin thread counter C;
4 = Bobbin thread monitor
o
06 01 0,1
999,9
300,0
x o0602
R
eset value
of the bobbin thread counter A
o
06 02 0,1
999,9
200,0
x o0604
R
eset value
of the bobbin thread counter B
o
06 03 0,1
999,9
100,0
x o0604
R
eset value
of the bobbin thread counter C
o
06 04 1
255
10
x stitches
Factor of the bobbin thread counter A, B, and C
o
06 05 0
9999
0
stitches
Number of stitches for bobbin thread monitor
o
06 06 0
1
0
-
Stopping motor if the counter has reached the value 0.
0 = off;
1 = on
o
06 07 0
1
0
-
Sewing foot down after thread trimming.
0 = off;
1 = on
o
06 08 0
1
0
-
Display of the bobbin thread counter value
0 = off;
1 = on
Needle cooling
o
13 00 0
1
0
-
Needle cooling
0 = off;
1 = on