Operating manual part II
II-16
© 2010 Dürkopp Adler AG
L
C
P
Min
Max
Preset Unity
Description
t
52 20 0
13
1
-
Function of the input “F
0 = no function;
1 = on threading help;
2 = Bartack suppression/recall;
3 = Manual bartack;
4 = Half stitch;
5 = Full stitch;
6 = Direction finder position;
7 = Turning back
8 = Input function module 1;
9 = Input function module 2;
10 = Input function module 3;
11 = Switch high lift for walking foot;
12 = Ornamental Backtack;
13 = Needle cooling
t
52 40 0
1
0
-
Key lock for the initial bartack buttons
0 = No;
1 = Yes
t
52 41 0
1
0
-
Key lock for the final bartack buttons
0 = No;
1 = Yes
t
52 42 0
1
0
-
Key lock for the thread buttons
0 = No;
1 = Yes
t
52 43 0
1
0
-
Key lock for the seam program buttons
0 = No;
1 = Yes
t
52 44 0
1
0
-
Key lock for the programming buttons
0 = No;
1 = Yes