Maintenance
86
Service Instructions 969 - 01.0 - 12/2015
Fig. 58: Lubricating the needle bar
Steps
1. Remove the head cover.
2. Place the grease gun onto the lubricating nipple (1) on the needle
bar frame (2) and keep pressing until the flow of grease stops.
The lubricating nipple (1) is used to lubricate the needle bar and the
feeding bar of the presser foot.
3. Loosen the setscrew (3) from the needle bar frame (2).
4. Press a small amount of grease into the opening of the setscrew (3)
to lubricate the upper part of the needle bar.
5. Screw the setscrew (3) back in.
6. Install the head cover.
(1) - Lubricating nipple
(2) - Needle bar frame
(3) - Setscrew
①
②
③