![Duratech megavoice 2000 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/duratech/megavoice-2000/megavoice-2000_installation-manual_2541488021.webp)
5.14 ANSWER DELAY 57
V
57 c
V
nn #
c = Line number (1...6)
nn = value 1...9 or 10.99. If
V
= display the value. Default is 1
rings
Megavoice sets the line c to have answer delay of nn
rings
. One ring has a minimum
lenght and maximum delay between rings of 6.2s. This delay is used if the line type has
delayed answer. Megavoice replays with a OK tone and displays the value L=cc RING=nn.
Note : Do not give too high value or you may not be able to enter the programming mode.
See also 5.16 ja 5.17.
LINE L ANSWER DELAY ( default )
1
(1)
2
(1)
5.15 PARAMETERS 59
V
59 pp
V
nn #
, Set a value for a parameter nn.
V
59 pp
V V
#
, Display the value
pp= parameter number 1...9 or 01...99, nn= value 0...256 (there can be a limitation)
These parameters set up advanced technical features.
Megavocei sets up parameters with a value. Finally OK tone is replayed.
Display indicates : PA=pp VAL =nn.
Parameter Default
Unit Value Total
Explanation
par
nn
ms
01
12 10 ms 12 x 10 ms = 120 ms.
Flash time.
02
10 100 ms 10 x100ms=1s Delay bw last DTMF digit
and release.
03
12 100 ms 20 x100ms=1.2 s Start delay before a message
04
03 number
Mode switch
05
01 number
SW mode, MV=01.
Used setting is value * unit.
Parameter 01
Flash time. The lenght of loop brake state during transfer flash. Too
short flash do not work and the caller hears DTMF-tones. Too long value cuts the call.
Sometimes th best value is the mean value of the maximum and minimum tested
operational values.
Parameter 02
Delay between last DTMF digit and release of the line.
Parameter 03
Extra dely for line 1 between answer and start of message to enter
programming state. The base delay is 2s and this is added to it.
Parameter 04
Value=01. Normal state. No mode switch in use.
Value=02. Mode switch is used. Front panel mode switch (and sw1,2
and E1 and E2-wires) sets the current operational mode ( day/night/
vacation/programming). If the switch is switched of the Programming,
the line is released.
Value=03. As 02 and Megavoice enters the programming state
immediately if the mode switch is in Programming state.
17