3. INSTALLATION
3.1 MECHANICAL INSTALLATION
Megavoice is placed into a suitable place and line cable kit is connected to the D25
connecter in the front panel. The power supply is connected. The extention line are
connected to the line cable. See schematics for details. One line can be connected to
tele line or 600 ohm line. Also E&M signaling can be used. A additonal 2x16 character
display can be connected to Display-connector.
3.2 QUICK START
GENERAL
- OK is 2 beeps,
- Wait/infomation tone is one beep,
- Error tone is 9 beeps.
- All commands start with
V
and end with #. Detailled commands are in installation
manual.
1. Install Megavoice cables.
1B If front panel mode switch is used : Place mode switch into Program state.
2. Ring line 1. Its extention number is _____________. ( Installer fills in)
If necessary dial DTMF sending start prefix _________ ( == )
3A. If mode switch is used : Wait for 2 beeks, OK.
3B. Else : Dial
V
0 pppppp #, (login) immediately the device answers. Password here is
pppppp, see 3.4. Programming state is reached this way. If password is not used
V
0 #,
can be used. Megavoice answers with OK beeps. If not try call again.
4. Play an old message 1.
Dial command
V
3 1#. Device plays back message 1. This way m -message is played
back with
V
3 m # command. # stops playing
5. Erase old message 1. Dial
V
1 1 #. This way m-message is erased with
V
1 m #.
Device beeps till it gives OK beep. Message 9= guiding tone and it can only be erased
with switch 8 =1.
6. Record message 1.
Dial command
V
2 1#. Wait 2 s for a start beep and record new message with a hand
set or CD with line connector. Stop with #. Device gives then OK beep. If error or out-of-
memory-error it gives error-tone.
7. Repeat steps 4...6 for necessary messages. The meaning of different messages are
hopefully written by installator to chapter 3.4
8. Now installer can enter other set ups. The line answer/delays, transfer target
numbers etc. must be entered. The set ups must be stored with *66# into non-volatile
memory in the end for power failures.Recordings are always stored.
9. Finally exit the programming state.
9A. If mode switch is used : Switch it off the Programming state and it cuts the line.
9B. Else: With
V
0 # command or the device logs out after 222s of no-commands-state.
10. Test the installation.
8
8
MEGAVOICE 2000 V.3.1 MANUAL V.2000-09-20