9. Installation
The following installation advice should be followed step by step, to prevent damage to the system. In
the
’’Customer Specific Calculations for the D-FL 200“
(extra sheet enclosed with your system)
you can find the specific parameters for your application to install your system. There are also
the dimensions of your welding flanges. Please use it for your installation.
9.1. Mounting the Welding Flanges
The welding flanges should be mounted on the stack as shown in the drawing below. The flange tubes
should project slightly into the interior of the stack. This helps to prevent condensate from
accumulating. The standard angle is 45°. You have to ensure that there is enough space to build in the
measuring heads. The length of the measuring head depends on the respective wall thickness. The
standard lengths are listed in section
3.2. Transducer page 8 in the picture (Fig. 9) D-FL 200 flange
page 9. Ensure a safe access to the flanges for later maintenance.
Attention! The measuring heads may not be installed before the purge air system is connected and
running. Because missing of purge air they may become overheated and destroyed.
(Fig. 20) Recommended installation of the D-FL 200 welding flanges