SOLUTION
•  DO NOT light the burner.  Extinguish any open 

flame near the spill.  Wipe up the spill, and wait 

several minutes for the residue to evaporate.  

If you see no additional fuel on the ground, 

you may light the burner.  If you see additional 

fuel on the ground, you might have a leak.  DO 

NOT use this appliance if it leaks fuel.

•  The appliance may not be level.  Check 

to make sure the appliance is level, and 

shim under the grate legs or rear support, if 

necessary.  Shim only with metal washers or 

other non-flammable objects.

•  A small piece of foil that covers the 

opening of the illuma-fuel

®

 canister might 

be obstructing the piercer tube.  Open the 

fuel canister door on the left side of the 

appliance.  Gently wiggle the fuel canister 

left to right and front to rear on the fuel 

canister tray to enlarge the opening in the 

foil.  DO NOT lift the illuma-fuel canister from 

the tray, as this could cause a fuel spill.

•  The tubes connecting the burner to the fuel 

reservoir might be clogged.  Starting at the 

tube opening in the bottom of the burner, run 

a thin, flexible wire through the length of the 

tube to remove the obstruction.

•  The battery in the igniter may be dead.  

Replace it with a new battery

•  The sparker tip may be out of position.  The 

tip of the sparker should be about ¼” above 

the level of the sparking point.  Carefully 

bend the wire so that the tip of the sparker 

wire is in this position

•  The fuel is cold or the appliance is cold.  

Use a long match or a long butane lighter to 

ignite the fuel.

•  If the fuel is hot, the fuel vapors stop oxygen 

from being in the vicinity of the spark.  Thus 

not allowing the fuel to ignite.  Wait until the 

fuel is cool or relight the appliance using a 

long match or a long nosed butane igniter. 

PROBLEM
1. You see fuel on the ground near the 

appliance.

2. You do not see fuel in the burner prior to 

lighting the appliance and after installing a 

canister.

3. You push the igniter button but the appliance 

does not light.

XII. TROUBLESHOOTING

Use the following guide to solve any problems you might encounter in operating this appliance.

Содержание illuma 64000

Страница 1: ...tallation adjustment alteration service or maintenance can cause injury or property damage Refer to this manual for correct installation and operational procedures WARNING This appliance is designed for installation only in a solid fuel burning masonry fireplace a UL127 factory built fireplace or in an ANSI Z21 91 ventless firebox or on a table or cabinet There are no other standards for this type...

Страница 2: ...up 5 III Minimum Firebox Dimensions 7 IV Clearances 7 V Installing Damper Stop 7 VI Installation 7 VII Installing the Fuel Canister 10 VIII Operation 10 IX Refueling 12 X Adjustments 13 XI Maintenance 13 XII Troubleshooting 15 XIII Parts List 16 Warranty 17 ...

Страница 3: ...is placed away from curtains clothing or any other combustible material c When placed inside a fireplace make sure it is installed per instructions in this manual Never move this appliance while it is in operation or when there is still a flame in the burner no matter how small the flame is Moving the appliance while burning may cause spilling of fuel inside or outside the appliance which could re...

Страница 4: ...ster is completely empty WHAT TO DO IN THE EVENT OF A FUEL SPILL OR FUEL LEAK DO NOT light the burner Extinguish any open flame near the spill Wipe up the spill and wait at least 5 minutes for the residue to evaporate In addition to the potential for fire spilled duraflame illuma fuel can damage some surfaces like wood and leather Wipe up any spills immediately Install this appliance in compliance...

Страница 5: ...afely away from the device while igniting and while the appliance is in use Do not leave the appliance burning unattended Extinguish the flames before you leave the house go to bed or leave the room for an extended period of time Never leave children unattended near the appliance while it is in use Extinguish the flames by rotating the knob on the side this will close the burner cover and extingui...

Страница 6: ...ng codes In the absence of local codes use the latest edition of The National Fuel Gas Code ANSZ223 1 also known as NFPA54 available from American National Standards Institute National Fire Protection Association Inc 25 West 43rd Street 4th floor OR 1 Batterymarch Park New York NY 10036 Quincy Massachusetts USA 02169 7471 This appliance is designed to burn with very low emissions so that it requir...

Страница 7: ...ireplace and burner function as a system If the fireplace is spilling combustion gases into the room check draft with a match candle or smoke stick reposition the damper clamp to open the damper wider until a positive draft i e all combustion emissions go up the chimney is obtained VI INSTALLATION 1 Carefully remove the contents of the carton You should find The burner base Figure 1 Four 4 tempere...

Страница 8: ... option you can place loose decorative glass or small rocks in the areas between the front glass or back glass or both and the burner Make sure the top level of the loose material is not higher could be lower than the top of the burner The material has to be larger than 3 16 in size and smaller than 1 in size for each piece These materials could be purchased from your supplier or at the store you ...

Страница 9: ... 9 Figure 4 Placement of right glass panel Figure 3 Placement of rear glass panel Figure 6 Placement of front glass panel Figure 5 Placement of left glass panel ...

Страница 10: ...he fuel is about to run out You can refuel the appliance at this time see Section IX or let the flame die down VIII OPERATION WARNING If you do not follow these instructions exactly a fire may result causing property damage personal injury or loss of life NOTE During initial operation of the new appliance and at the beginning of each burn season the appliance may emit a slight odor This is normal ...

Страница 11: ...may not ignite using the sparker because the fuel is evaporating at a higher rate than usual and creates and oxygen free environment around the sparker If that happens either wait for a while for the fuel to cool down or ignite the fuel in the burner using a long match or a butane igniter In case you use a match or igniter when the fuel is hot be carefull not to have your face near the burner beca...

Страница 12: ... acts as a flame shield Please note that even though the area indicated in Figure 11 is cool areas of the door closer to the flame may be hot 2 Check the fuel canister and make sure IT IS EMPTY 3 Grasp the empty canister by the notches provided in the canister body see Figure 11 Pull it up and tip it so that it clears the bracket make sure the back side of the canister is tipped so it is lower tha...

Страница 13: ...eed more frequent cleaning due to excessive lint from carpeting bedding material pet hair etc The only maintenance needed for the continued good performance of this appliance is periodic cleaning at least once per year or more depending on frequency of use and checking for leaks Note that after some time heat might cause the stainless steel burner to discolor slightly This is natural To clean the ...

Страница 14: ...alled properly see Figure 12 The top surface of the piercer should be level If it is higher on the back end or on one side then turn it around and place it back in place again 6 Check for leaks by installing a fuel canister into the appliance and letting it sit for five minutes Check for leaks in the areas shown in Figure 10 before igniting the fuel Figure 12 How to install piercer ...

Страница 15: ...ng the burner to the fuel reservoir might be clogged Starting at the tube opening in the bottom of the burner run a thin flexible wire through the length of the tube to remove the obstruction The battery in the igniter may be dead Replace it with a new battery The sparker tip may be out of position The tip of the sparker should be about above the level of the sparking point Carefully bend the wire...

Страница 16: ... 16 XIII PARTS LIST Part Numbers 64001 Small Glass 64002 Large Glass 61002 Igniter 61007 Canister Tray Piercer 61010 Masonry Screws 61011 Sparker 64003 Hold Downs ...

Страница 17: ...duct and or Duraflame Inc which will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Correction in the manner provided above shall constitute a fulfillment of all liabilities of Duraflame Inc with respect to the quality of the product The product MUST be installed by a person capable of following all instructions in accordance with a...

Страница 18: ... the above limitation on implied warranties or exclusion or limitation on damages may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state For information about this warranty write to Attn Consumer Affairs Duraflame Inc 2894 Monte Diablo Ave Stockton CA 95203 www duraflame com ...

Отзывы: