Duracraft DCMKP33T Скачать руководство пользователя страница 3

For parts or assistance, call Duracraft Customer Service at 

1-888-749-5759

Installation and Operation

3

To reduce risk of electric shock,

pull plug before servicing. This pump has not
been investigated for use in swimming pool
areas. Pump is supplied with a grounding con-
ductor and grounding-type attachment plug. Be
sure it is connected only to a properly grounded
grounding-type receptacle.
Where a 2-prong wall receptacle is encoun-
tered, it must be replaced with properly
grounded 3-prong receptacle installed in accor-
dance with codes and ordinances that apply.

13.  All wiring should be performed by a qualified

electrician.

14. Make certain power source conforms to require-

ments of your equipment.

15. Protect electrical cord from sharp objects, hot

surfaces, oil, and chemicals. Avoid kinking cord.
Replace or repair damaged or worn cords imme-
diately.

16. Do not touch an operating motor. Modern motors

can operate at high temperatures.

17. Do not handle pump or pump motor with wet

hands or when standing on wet or damp surface,
or in water.

Hazardous voltage can shock, burn or

kill. If your basement has water or moisture on
floor, do not walk on wet area until all power has
been turned off. If shut-off box is in basement, call
electric company or hydro authority to shut-off ser-
vice to house, or call your local fire department for
instructions. Remove pump and repair or replace.
Failure to follow this warning can result in fatal
electrical shock.

Do not lift pump by power cord.

INSTALLATION

1. Install pump in sump pit with minimum diameter

of 14" (356mm). Sump depth should be 16"
(406mm). Construct sump pit of tile, concrete,
steel or plastic. Check local codes for approved
materials and for proper installation.

2. Install pump in pit so that switch operating

mechanism has maximum possible clearance.

3. Pump should not be installed on clay, earth or

sand surfaces. Clean sump pit of small stones
and gravel which could clog pump. Keep pump
inlet screen clear.

NOTICE:

Do not use ordinary pipe joint com-

pound on plastic pipe. Pipe joint compound can
attack plastics.

4. Install discharge plumbing. Use rigid plastic pipe

and wrap threads with Teflon

TM

tape. Screw pipe

into pump hand tight plus 1-1/2 turns.

Risk of flooding. If a flexible dis-

charge hose is used, make sure pump is
secured in sump to prevent movement. Failure
to secure pump may allow pump movement,
switch interference and prevent pump from
starting or stopping.

5. To reduce motor noise and vibrations, a short

length of rubber hose (1-7/8" (47.6mm) I.D., e.g.
radiator hose) can be connected into discharge
line near pump using suitable clamps.

6. Install an in-line check valve or an in-pump check

valve to prevent flow backwards through pump
when pump shuts off.

NOTICE:

If your check valve is not equipped with

an air bleed hole to prevent airlocking pump, drill
a 1/8" (3.2 mm) hole in discharge pipe just above
where the discharge pipe screws into the pump
discharge. Be sure the hole is below the waterline
and the check valve to prevent air locks. 

7. Power Supply: Pump is designed for 115 V., 60

Hz., operation and requires a minimum 15 amp
individual branch circuit. Both pump and switch
are supplied with 3-wire cord sets with ground-
ing-type plugs. Switch plug is inserted directly
into outlet and pump plug inserts into opposite
end of switch plug.

Pump should always be electrical-

ly grounded to a suitable electrical ground such
as a grounded water pipe or a properly ground-
ed metallic raceway, or ground wire system.
Do not cut off round ground pin.

8. If pump discharge line is exposed to outside sub-

freezing atmosphere, portion of line exposed
must be installed so any water remaining in pipe
will drain to the outfall by gravity. Failure to do
this can cause water trapped in discharge to
freeze which could result in damage to pump.

9. After piping, check valve and float switch have

been installed, the unit is ready for operation.

10. Check the pump operation by filling sump with

water and observing pump operation through one
complete cycle. For switch settings see the Electrical
and Switch Specifications chart on Page 2.

Failure to make this operational

check may lead to improper operation, prema-
ture failure, and flooding.

TM

E.I. DuPont De Nemours and Company Corporation, Delaware.

Содержание DCMKP33T

Страница 1: ...ion Operation Parts For further operating installation or maintenance assistance Call 1 888 749 5759 English Pages 2 7 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utili...

Страница 2: ...ies For more infor mation see your retailer call Duracraft customer service at 1 888 749 5759 or visit our website at www duracrafttools com 1 Know the pump application limitations and potential hazar...

Страница 3: ...pe joint compound can attack plastics 4 Install discharge plumbing Use rigid plastic pipe and wrap threads with TeflonTM tape Screw pipe into pump hand tight plus 1 1 2 turns Risk of flooding If a fle...

Страница 4: ...r before dam age can be done to motor When motor has cooled sufficiently switch will reset automatically and restart motor If protector trips repeatedly pump should be removed and checked as to cause...

Страница 5: ...d Assembly 1 PS117 54 TSU 2 Tethered Float Switch Assembly 1 FP18 15BD 3 Cord Clamp Screw 1 U30 955PS 4 Float Switch Cord Clamp 1 CC0030 13 5 Screw 8 32x7 8 Hex Head 4 U30 951PS 6 Motor 1 7 Volute Upp...

Страница 6: ...loat switch Replace float switch Restricted discharge Remove pump and clean pump and piping obstacle or ice in piping Float obstructed Remove obstruction Restricted intake screen Remove the pump and c...

Страница 7: ...ot limited to operational failures caused by corrosion rust or other foreign materials in the system or operation at pressures in excess of recommended maximums Requests for service under this warrant...

Страница 8: ...s rem des Pour de plus amples renseignements s adresser au d taillant appeler le service la client le Duracraft en composant le 1 888 749 5759 ou visiter notre site web www duracrafttools com 1 Avant...

Страница 9: ...re pour tuyaux filet s sur les tuyaux en plastique car cette p te attaque les plastiques 4 Poser la tuyauterie de refoulement Utiliser des tuyaux en plastique rigide et envelopper les filets de ruban...

Страница 10: ...terrompra automatiquement l arriv e de courant avant que le moteur soit endommag Lorsque le moteur aura suffisamment refroidi le disjoncteur se r armera automatiquement et le moteur red marrera Si le...

Страница 11: ...ble de cord n lectrique 1 PS117 54 TSU 2 Interrupteur flotteur cordon 1 FP18 15BD 3 Vis t te de collier cordon 1 U30 955PS 4 Collier cordon de interrupteur flotteur 1 CC0030 13 5 Vis t te hexagonale n...

Страница 12: ...rrupteur du flotteur d fectueux La pompe refuse de Interrupteur du flotteur Remplacer l interrupteur du flotteur s arr ter d fectueux Diminution du refoulement D poser la pompe et nettoyer la pompe et...

Страница 13: ...par la corrosion la rouille ou autre corps tranger dans le syst me ou des produits ayant fonctionn des pressions d passant la limite maximale recommand e Les demandes de service en vertu de la pr sen...

Страница 14: ...e la bomba de sum idero y soluciones Para mayor informaci n visite a su representante de ventas llame al Departamento de Servicio al Cliente de Duracraft 1 888 749 5759 o visite nuestro sitio en Inter...

Страница 15: ...on cinta de Tefl n TM Enrosque la tuber a en la bomba a mano y despu s apri tela 1 1 2 vueltas Riesgo de inundaci n Si se usa una manguera de descarga flexible aseg rese de que la bomba est bien inmob...

Страница 16: ...r toda la energ a antes de que se produzca da o al motor Cuando el motor se ha enfriado suficientemente el interruptor se reposi cionar autom ticamente y el motor volver a pon erse en marcha Si el pro...

Страница 17: ...riente 1 PS117 54 TSU 2 Unidad del interruptor de flotador anclado 1 FP18 15BD 3 Tornillo de abrazadera de cordon 1 U30 955PS 4 Abrazadera de cordon del conmutador flotaci n 1 CC0030 13 5 Tornillo cab...

Страница 18: ...el flotante est fallado Reemplace el interruptor del flotante La bomba no se Interruptor defectuoso Reemplace el interruptor del flotante desconecta del flotante Descarga obstruida Retire la bomba y l...

Страница 19: ...endo pero no limitado a fallas operacionales causadas por corrosi n oxidaci n u otros elementos extra os en el sistema o funcionamiento a presi n por encima del m ximo recomendado Los pedidos de servi...