Duracraft DCMKP33T Скачать руководство пользователя страница 2

For parts or assistance, call Duracraft Customer Service at 

1-888-749-5759

Specifications and Safety

2

DESCRIPTION

This Submersible Sump Pump is designed for home
sumps. Unit is equipped with a 3-prong grounding-type
power cord. Shaded-pole motor is oil filled and sealed
for cooler running. Sleeve bearings on motor shaft never
need lubrication. Automatic reset thermal protection. Not
designed for use as a swimming pool drainer.

SPECIFICATIONS

Power supply required ...........................115V, 60 HZ.
Liquid Temp. Range ................32°F to 70°F(0°-21°C)
Individual Branch Circuit Required (min.) ....15 Amps
Discharge: ........................1-1/4" FNPT / 1-1/2" MNPT

NOTICE:

Do not reduce size of discharge pipe or

hose below 1-1/4” diameter. If discharge is too
small, pump will overheat and fail prematurely.
Pump water only with this pump.

NOTICE:

This unit is not designed as a waterfall or foun-

tain pump, or for applications involving salt water or
brine! Use with waterfalls, fountains, salt water or brine
will void warranty.
Do not use where water recirculates.
Not designed for use as a swimming pool drainer.

PERFORMANCE

ELECTRICAL & SWITCH SPECIFICATIONS

GENERAL SAFETY INFORMATION

Electrically powered sump pumps normally give
many years of trouble-free service when correctly
installed, maintained, and used. However, unusual
circumstances (interruption of power to the pump,
dirt/debris in the sump, flooding that exceeds the
pump’s capacity, electrical or mechanical failure in
the pump, etc.) may prevent your pump from func-
tioning normally. To prevent possible water damage
due to flooding, consult your retailer about a sec-
ondary AC sump pump, a DC backup sump pump,
and/or a high water alarm. See the “Troubleshooting
Chart” in this manual for information about common
sump pump problems and remedies. For more infor-
mation, see your retailer, call Duracraft customer 
service at 1-888-749-5759 or visit our website at
www.duracrafttools.com.
1. Know the pump application, limitations, and

potential hazards.

2.

The oil-filled motor was not designed for use in
water containing fish. Do not use this pump in
water with fish present.

3. Disconnect power before servicing.
4. Release all pressure within system before servic-

ing any component.

5. Drain all water from system before servicing.
6. Secure discharge line before starting pump. An

unsecured discharge line will whip, possibly
causing personal injury and/or property damage.

7. Check hoses for weak or worn condition before

each use, making certain that all connections are
secure.

8. Periodically inspect sump, pump and system

components. Keep free of debris and foreign
objects. Perform routine maintenance as
required. 

9. Provide means of pressure relief for pumps whose

discharge line can be shut-off or obstructed.

10. Personal Safety:

a. Wear safety glasses at all times when working

with pumps.

b. Keep work area clean, uncluttered and prop-

erly lighted – replace all unused tools and
equipment.

c. Keep visitors at a safe distance from work

area.

d. Make workshop child-proof – with padlocks,

master switches, and by removing starter
keys.

11. When wiring an electrically driven pump, follow

all electrical and safety codes that apply.

12.

This equipment is only for use on 115 volt (sin-
gle phase) and is equipped with an approved 
3-conductor cord and 3-prong, grounding-type
plug.

GPH (LPH) AT TOTAL FEET (M) OF LIFT

Motor

5

10

15

Series

HP

(1.5m)

(3m)

(4.6m)

CAPACITY GALLONS(L)/HOUR

DCMKP33T

1/3

2760

2160

1410

20 Ft.

(10 448)

(8 176)

(5 337)

(6.1M)

DCMKP50T 

1/2

3200

2700

2000

24 Ft.

(12 113) (10 220)

(7 571)

(7.3M)

No flow 

at height

shown

below

Individual

Motor

Branch

*Switch Setting

Motor Full Load

Circuit

in inches (mm)

Series

HP

Amps

Req.(Amps)

On

Off

DCMKP33T

1/3

5.5

15

13"(330)

6"(152)

DCMKP50T

1/2

9.0

15

13"(330)

6"(152)

Содержание DCMKP33T

Страница 1: ...ion Operation Parts For further operating installation or maintenance assistance Call 1 888 749 5759 English Pages 2 7 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utili...

Страница 2: ...ies For more infor mation see your retailer call Duracraft customer service at 1 888 749 5759 or visit our website at www duracrafttools com 1 Know the pump application limitations and potential hazar...

Страница 3: ...pe joint compound can attack plastics 4 Install discharge plumbing Use rigid plastic pipe and wrap threads with TeflonTM tape Screw pipe into pump hand tight plus 1 1 2 turns Risk of flooding If a fle...

Страница 4: ...r before dam age can be done to motor When motor has cooled sufficiently switch will reset automatically and restart motor If protector trips repeatedly pump should be removed and checked as to cause...

Страница 5: ...d Assembly 1 PS117 54 TSU 2 Tethered Float Switch Assembly 1 FP18 15BD 3 Cord Clamp Screw 1 U30 955PS 4 Float Switch Cord Clamp 1 CC0030 13 5 Screw 8 32x7 8 Hex Head 4 U30 951PS 6 Motor 1 7 Volute Upp...

Страница 6: ...loat switch Replace float switch Restricted discharge Remove pump and clean pump and piping obstacle or ice in piping Float obstructed Remove obstruction Restricted intake screen Remove the pump and c...

Страница 7: ...ot limited to operational failures caused by corrosion rust or other foreign materials in the system or operation at pressures in excess of recommended maximums Requests for service under this warrant...

Страница 8: ...s rem des Pour de plus amples renseignements s adresser au d taillant appeler le service la client le Duracraft en composant le 1 888 749 5759 ou visiter notre site web www duracrafttools com 1 Avant...

Страница 9: ...re pour tuyaux filet s sur les tuyaux en plastique car cette p te attaque les plastiques 4 Poser la tuyauterie de refoulement Utiliser des tuyaux en plastique rigide et envelopper les filets de ruban...

Страница 10: ...terrompra automatiquement l arriv e de courant avant que le moteur soit endommag Lorsque le moteur aura suffisamment refroidi le disjoncteur se r armera automatiquement et le moteur red marrera Si le...

Страница 11: ...ble de cord n lectrique 1 PS117 54 TSU 2 Interrupteur flotteur cordon 1 FP18 15BD 3 Vis t te de collier cordon 1 U30 955PS 4 Collier cordon de interrupteur flotteur 1 CC0030 13 5 Vis t te hexagonale n...

Страница 12: ...rrupteur du flotteur d fectueux La pompe refuse de Interrupteur du flotteur Remplacer l interrupteur du flotteur s arr ter d fectueux Diminution du refoulement D poser la pompe et nettoyer la pompe et...

Страница 13: ...par la corrosion la rouille ou autre corps tranger dans le syst me ou des produits ayant fonctionn des pressions d passant la limite maximale recommand e Les demandes de service en vertu de la pr sen...

Страница 14: ...e la bomba de sum idero y soluciones Para mayor informaci n visite a su representante de ventas llame al Departamento de Servicio al Cliente de Duracraft 1 888 749 5759 o visite nuestro sitio en Inter...

Страница 15: ...on cinta de Tefl n TM Enrosque la tuber a en la bomba a mano y despu s apri tela 1 1 2 vueltas Riesgo de inundaci n Si se usa una manguera de descarga flexible aseg rese de que la bomba est bien inmob...

Страница 16: ...r toda la energ a antes de que se produzca da o al motor Cuando el motor se ha enfriado suficientemente el interruptor se reposi cionar autom ticamente y el motor volver a pon erse en marcha Si el pro...

Страница 17: ...riente 1 PS117 54 TSU 2 Unidad del interruptor de flotador anclado 1 FP18 15BD 3 Tornillo de abrazadera de cordon 1 U30 955PS 4 Abrazadera de cordon del conmutador flotaci n 1 CC0030 13 5 Tornillo cab...

Страница 18: ...el flotante est fallado Reemplace el interruptor del flotante La bomba no se Interruptor defectuoso Reemplace el interruptor del flotante desconecta del flotante Descarga obstruida Retire la bomba y l...

Страница 19: ...endo pero no limitado a fallas operacionales causadas por corrosi n oxidaci n u otros elementos extra os en el sistema o funcionamiento a presi n por encima del m ximo recomendado Los pedidos de servi...

Страница 20: ......

Отзывы: