5.4 Preparation
Installation of the equipment is carried out based on the system design and the place in which the equipment is installed.
The installation must be carried out with the equipment disconnected from the grid (power disconnect switch open)
and with the photovoltaic modules shaded or isolated.
Refer to the Technical Data to make sure the environmental conditions fit the microinverter’s requirement (degree
of protection, temperature, humidity, altitude, etc.)
To avoid power de-rating due to an increase in the microinverter internal temperature, do not expose it to direct
sunlight.
IMPORTANT! To avoid overheating, always make sure the air flow around the inverter is not blocked.
Do not install in places where gasses or flammable substances may be present.
Avoid electromagnetic interference that can compromise the correct operation of electronic equipment.
When choosing the position of installation, comply with the following conditions:
Install only on structures specifically conceived for photovoltaic modules.
Install the microinverter underneath a photovoltaic module to shade it from direct sunlight.
D350-M1
D700-M2
D1500-M4
Installation Manual