Version
1.0
(2016)
Page
6
1.
Install fourAA-size 1.5V batteries into the remote receiver box(Fig 8).The systemoperates wellwithall
batteries’total output voltage is greater than 5.2V. Generally, four NEWAA-size batteries should output voltage of6.0
to6.2 volts if installed in series.
2.
Attach wall mount cover plate toreceiver box (Fig. 11). Press the receiver and haveit snap into top& bottom tabs
ofcover plate.
3. Position the cover plate to have words facing up (Fig. 12) Install the remote receiver box into the wallswitch
boxwithtwo provided switch box long screws.
NOTE
:The remote receiver box will only receivesignal fromthe transmitter in the REMOTEposition(middle). The remote
receiver box code mustbe matched tothe transmitter prior toinitial use (see
LEARNING TRANSMITTER TO RECEIVER
).
HEARTHMOUNT
The remote receiver box can be placed on the fireplace, under the fireplace, behind the control panel orlouvers....etc.Keep
away from high-heat, exceeding 130°F. Additional protection required for no exposure to the hearth.TheSlide switch button
should be installed on the receiver box forHearth Mount (Fig. 13).
WIRINGINSTRUCTIONS
ONLYqualified electrician / gas technician with the knowledge of gas appliances and gas valves that are permittedto install
the remote control system.Incorrect wiring installationwilldamagethe gas valve, electronic module of gas appliance and also
the remote receiver.
a.
WIRING MILLIVOLT VALVE (Fig. 14)
Connect the two 18 gauge stranded or solid wires of the Remote receiver box to the Millivolt gas valve at the TH & TH/TP
terminals on the terminal block. It does not matter which wire go to which terminal.
The remote receiver box‘s operation is similar to a thermostat that also turn the gas valve ON and OFF based on the input
signals from TH & TH/TP terminals. Transmitter sends signals to receiver box, and receiver box pass the signals to Millivolt
valve to function the ON and OFF of fire / heater.
Fig. 14
b.
WIRING ELECTRONIC SPARK IGNITION MODULE (Fig. 15)
Connecta 24VAC transformer in series to the TR (transformer) terminal on the ELECTRONIC MODULE. Connect the hot
wire from the 24VAC transformer to either of the wire terminals on the remote receiver box. Connect another wire