185232
38
Soft Serve Freezer Model GEN-102
14. Place an empty container under the
dispense heads.
15. Pull the air bleed plugs up until they
touch the bottom of the switch box.
Open the spigots.
16. Turn the MTS pumps “ON”. When
sanitizer flows out the bottom of the
head, close the air bleed plugs and
allow the MTS to pressurize the
cylinders.
17. Press L1 & R1 to turn the beaters
“ON” and allow them to agitate for 5
minutes.
11.1 Draining Product (continued)
IMPORTANT:
Do NOT use the “FREEZE” position
with sanitizer or water in the cylinder.
The freezer will be damaged.
18. Slowly open the spigots and allow
the MTS to push the sanitizer out of
the cylinders. Leaving the spigots
open, turn the beaters “OFF”. Leave
the MTS pumps “ON” and allow the
pumps to force all remaining sanitizer
from the cylinders. When sanitizer
quits flowing, place the MTS pump
switches to “OFF”
19. Remove the pickup tubes from the
sanitizing solution.
20. Refer to Disassembly and Cleaning
Instructions.
11.2
Night Switch Operation
1. In areas where health codes will allow,
the freezer may be switched to night
mode operation. This will allow the
freezer to cycle all night and maintain
approximately 36°F (2.2°C) product in
the cylinders and cabinet.
2. To switch the freezer to Night mode,
press the Soft key located below the
image of the Moon on the display.
(Pictured Below)
3. Remove any spigot extensions
and spigot extension o-rings that
might be installed, remove the drip
tray assembly and clean all soiled
surfaces with soap and water. Fill
LEFT
RIGHT
ON
ON
CABINET
ON
37
0
F
Press to enter Night mode
Figure 11-2
NOTICE
The “night” mode operation is not
to be used in lieu of proper cleaning
and sanitization procedures at the
frequencies required by the federal,
state, or local regulatory agency.
the wash bottle (HC196103) with
approved sanitizing solution, using
the wash bottle and a brush clean the
spigots and openings.
4. Repeat step 3 prior to putting the
machine back into day mode for the
days use.
Содержание DQ GEN-102
Страница 2: ......
Страница 10: ......
Страница 20: ...185232 10 Soft Serve Freezer Model GEN 102 5 Part Names and Functions Figure 5 1 Head Assembly...
Страница 82: ......
Страница 84: ......
Страница 100: ...185232 16 Soft Serve Freezer Model GEN 102 Figure 12 Side Rear View WC...
Страница 105: ...185232 21 Soft Serve Freezer Model GEN 102 O Ring Chart...