185232
35
Soft Serve Freezer Model GEN-102
10.1
Sanitizing (continued)
12. Leaving the spigots open, press L1 &
R1 keys to turn the beaters “OFF” and
let the MTS force all possible sanitizer
out of the freezing cylinders.
13.
NOTE:
Some sanitizer will remain in
hoses and cylinder.
to the probes and to the back of the
cabinet.
6. Close the cabinet door.
7. Place an empty container under the
dispense head on the drip tray.
8. Pull up the air bleed plugs
9. Open the side spigots.
10. Press L2 & R2 keys to turn the MTS
pumps “ON” allowing the mix to push
the remaining sanitizer from the
freezer.
11. Close the spigots one at a time when
pure mix is coming out.
Important:
Failure to completely remove
sanitizer or water from the freezing
cylinder before placing in “FREEZE”
will cause the scraper blades to break
and damage the freezer.
12.
Allow the MTS to fill the cylinder until
mix flows from the bottom of the air
bleed plug openings in the bottom of
the dispense head, close the air bleed
plugs. Wait for the MTS to fill the
cylinders and shut off.
13. After the cylinders are pressurized
and the MTS has cycled off
(approximately 30 seconds) Press the
left and right “Freeze” keys.
14. Allow the freezer to cycle for 15-20
minutes. The product is now ready to
serve.
1. Wash and sanitize your hands and
forearms.
2. Holding the top 6-inch (15cm) portion
only, insert each pickup tubes into the
sanitized mix tank through the small
hole in the rear cover and set tanks in
the cabinet.
3. Slide each boot seal down on the mix
tank cover.
4. Fill the mix tanks with mix and install
the front covers.
5. Insert each sanitized mix probes
through the large hole in the rear
cover, and connect the probe cords
10.2
Priming
Priming the freezer removes all excess air and sanitizer from the freezing cylinder
and sets the proper overrun for the first cylinder of product.
Figure 10-1
14. Press L2 & R2 keys to turn the MTS
pumps “OFF”.
15. Remove the pickup tubes, holding the
top 6” portion only.
16. Remove the mix tanks and empty any
remaining sanitizer.
PORT AIR/MIX ASSEMBLY
CORDSET-MIX LEVEL
AIR METER
AIR METER TUBE
SWING CLOSED
ROLLER SHOE
ROLLER SHOE
MIX TRANSFER HOSE
NO TWIST. NOTE RED LINE
BRAIDED HOSE ASSY
RETAINER-AIR LINE
CYLINDER INLET
CONNECT THIS CLAMP LAST
HOSE CLAMPS
PUMP COVER
SWING IN SHOE
CLAMP
Содержание DQ GEN-102
Страница 2: ......
Страница 10: ......
Страница 20: ...185232 10 Soft Serve Freezer Model GEN 102 5 Part Names and Functions Figure 5 1 Head Assembly...
Страница 82: ......
Страница 84: ......
Страница 100: ...185232 16 Soft Serve Freezer Model GEN 102 Figure 12 Side Rear View WC...
Страница 105: ...185232 21 Soft Serve Freezer Model GEN 102 O Ring Chart...