Soft Serve Freezer Model GEN-102
CAUTION
To prevent accidental electrical
shock, a positive earth ground
is required.
2.4
Electrical Connections
Important!
A positive earth ground is required for
electronic VQM system
to operate correctly.
1. Double freezers with two compressors
require one power supply for each
side of the freezer. Each side of the
freezer operates independently.
2. Check the data plate for fuse
size, wire ampacity, and electrical
specifications. (See Figure 3-2)
3. Refer to the wiring diagram provided
for proper power connections.
4. Electrical connections are made in
the junction boxes located mid-level
behind the left side panel.
Important
Set switch next to the connection
box “UP” for 220-230v or “DOWN”
for 208-219V. Failure to set switch to
proper voltage will cause damage to
the electrical components and will void
all warranties.
5.
Use a flexible connection when
permissible.
6. For 3 phase freezers, beater shaft
rotation must be clockwise as viewed
from the front of the freezer.