9.6.
Learning Radio Zones
9.7.
Programming Zone
Programming the type of insertion and activation of each zone:
9.8.
Programming ALERT
9.9.
Exit Time (seconds)
9.10.
Entry Time (seconds)
9.11.
Pre-alarm time in Seconds
Learning X
Radio Zone 01 P
Prog. Zone R
Radio Zone 01 P
At each press, it will move to the next zone (Wired
Zones and Radio Zones)
Short press changes the status:
R
= sensor with Entry Time
I
= Instantaneous alarm sensor
D
= sensor Disabled
Long press changes insertion:
T
= Total
P
= Partial
E
= External
Prog. Zone I
Radio Zone 01 P
Prog. Alert D
Radio Zone 01 P
Time for exit in seconds
Press 1 time to start count from zero.
Press again to stop the count at the desired value.
Exit Time (sec)
10
Time for entry in seconds
Press 1 time to start count from zero.
Press again to stop the count at the desired value.
Entry Time (sec)
10
Time of PreAlarm in seconds
Press 1 time to start count from zero.
Press again to stop the count at the desired value.
PreAlarm (sec)
00
Programming ALERT warning sound
(See USERS MANUAL)
Learning Sensors
See “LEARNING WIRELESS ZONES” section