8
ENGLISH
L2000641 Installation guide for DucoBox Silent (Revision H | 13.07.2020)
04
Wiring
04.A
Connector & buttons
Boxsensor 2
Boxsensor 1
HIGH
DOWN
LOW
ENTER
INST
UP
Power
230 VAC
Fan
Duco
Wired
Antenna
Duco
Network
Tool
Switch
Contact
(n132)
GND
B
A
Blue Yellow
Red
White
Connector for
Communication Print
04.B
Cabling diagram
The DucoBox Silent Connect is able to communicate with Duco slave components via a wireless (RF) or wired link� Both types of
communication can be combined in one system�
Communication with non-Duco components is possible via the Switch Sensor or one of the connections on the optional Communi-
RF
RF
Wired
RF
24 VDC
24 VDC
24 VDC
230 VAC
230 VAC
A
A
B
B
GND
GND
B
A
GND
POWER
SUPPLY
User controller
User controller
Max 99 Wired
+ 25 RF
Tronic vent
Tronic vent
230 VAC
230 VAC
DucoBox
Silent Connect
RF obstacle-free zone
Do not place any obstacles causing RF
interference or other devices with an RF
connection within a radius of at least 30 cm
around the RF component� We take these to
include items such as washing machines,
tumble dryers, ironing boards, etc�
≥ 30 cm
Strain relief
It is mandatory to place the power supply cable in the slot provided, as shown in the drawing, before powering up the DucoBox�
Illustrations and connections may vary depending on product configuration�
Incorrect connection or failure to follow the instructions may result in
damage to the connected devices�