Ducasa Vitro-i 1200 Black Скачать руководство пользователя страница 8

8

9

When  the  temperature  setup  icon 

  starts  

flashing, press OK to  scroll through each mode.

Press the +/- button to change the temperature 

of each mode then press 

OK

 to confirm and go to 

the next MODE and exit to the temperature setting 

screen by pressing CONFIG.

To start programming press and hold 

CONFIG/

PROG

  button  for  3  seconds  and  the  following 

screen will appear:

Programming  starts  on  Monday  at  00:00  and 

is  set  by  choosing  the  required  Mode  for  each 

hour of the week. Use the 

OK

 button to choose 

between  Comfort 

,  Economy 

 or Frost   

Protection  modes.    On  the  screen  programme 

hours will show two  blocks for Comfort, one block 

for Economy and no blocks for frost protection). 

After choosing the mode  press the +/- buttons to 

select the next hour to be programmed. When a 

full day  has been programmed the screen moves 

to the  next day.

Once  each  day  of  the  week  has  been 

programmed  the clock must be set. 

Press  the 

CONFIG

  button  to  exit  from 

programming screen and  enter the time setting 

screen. 

To select the day of the week (1=Mon, 7=Sun)  

press +/- buttons and confirm with the 

OK

 button. 

Next select the  hour, confirm with 

OK

 and then  

select the minutes and confirm pressing 

OK

 once 

more.

If  a  heater  is  paired  with  a 

 

Gateway,  time  setting  is  not    required  as  it 

recognises the  system’s time automatically.

Manual Programming

Setting Programme and Clock

To assist with programming the LCD screen is 

backlit and will stay illuminated for approximately 

10 seconds after the last button is pressed.

When  the  heater  is  operational  and  the  room 

temperature  is  lower  than  the  set  temperature 

the  heating  symbol    will  be  shown  indicating 

that the heater is producing heat. When the room 

temperature equals or is above the set temperature 

the heating symbol will not be present indicating 
the heater is not producing heat. 

The  following  screens  show 

OFF

AUTO

 and 

MANUAL

 modes. To chose diferent modes press 

MODE/OK

 button.

When  the  heater  is  in 

AUTO

  mode  the 

temperature can be changed by pressing the +/- 

buttons. This change will remain active until the 

next  programme  change  or  until  midnight  when 

the temperature will revert to the preset value. 

Use    the  +/-  keys  to    change  the  temperature 

when the heater is in  

MANUAL

 mode. 

Adjust Programmed Temperatures

Adjusting temperature in the following way will 

only effect the temperatures used for programmed 

modes. 

To change these set up temperatures press  the 

CONFIG

 button and the following screen appears:

Содержание Vitro-i 1200 Black

Страница 1: ...her reference Models Vitro i 750 Black Vitro i 1200 Black Vitro i 1600 Black Vitro i 750 White Vitro i 1200 White Vitro i 1600 White NOTE A qualified electrician must carry out the electrical installa...

Страница 2: ...2...

Страница 3: ...heater becoming hot it must not be positioned directly against or below infammable surfaces Do not dry clothes or towels on the heater nor leave fabrics magazines spray cans volatile substances or si...

Страница 4: ...4...

Страница 5: ...floor According to regulations the apparatus must be connected to the power supply by means of an all pole circuit breaker with a contact gap of at least 3mm or by a thermal magnetic circuit breaker...

Страница 6: ...n the lower slotted holes and mark through the upper slotted holes for the top fixing screws See Figure 3b Drill and plug for these screws In this manner the Vitro i heater will be mounted on the wall...

Страница 7: ...screen will be blank and the heater will lose connection with the Gateway Stand by function Press the Mode OK button until the symbol is present as shown in the following screen When the heater is in...

Страница 8: ...nd then select the minutes and confirm pressing OK once more If a heater is paired with a Gateway time setting is not required as it recognises the system s time automatically Manual Programming Setti...

Страница 9: ...ignored and Lock will be displayed on the screen To unlock keyboard once again press and hold and for 3 seconds until the word Lock disappears When the keypad is locked the heater will still receive...

Страница 10: ...will restore normal function in any of these situations After 30 minutes Increase of 0 2 C by minute from the point of activation Pressing any key on the Vitro i Heater Heater Reset Resetting the heat...

Страница 11: ...11...

Страница 12: ...nce please contact your supplier Waste Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This marking shown on the product...

Отзывы: