![Ducasa Vitro-i 1200 Black Скачать руководство пользователя страница 10](http://html.mh-extra.com/html/ducasa/vitro-i-1200-black/vitro-i-1200-black_instructions-for-operation-and-installation_2537517010.webp)
10
11
Firmware Version (C4)
It shows internal software installed in the
electronics.
Open Window detection (C5)
In order to save energy, if a window opens and
causes a sudden drop in temperature the Vitro-i
will stop heating.
By default this function is deactivated. To change
the status of the function, press the +,- button and
then press ok to confirm.
This function detects a temperature drop of
0.6ºC every minute over a period 4 minutes.
If the heater is heating, it will be disconnected
for 30 minutes and shows the Open Window icon
on the display.
The Vitro-i heater will restore normal function in
any of these situations:
• After 30 minutes
• Increase of 0.2ºC by minute from the point
of activation.
• Pressing any key on the Vitro-i Heater
Heater Reset
Resetting the heater will return all settings to the
factory defaults and will also delete any “pairing”
with a
Gateway. To activate
the RESET feature press the
OK
button and the
CONFIG
button for 10 seconds. The following
screen will appear:
To confirm the reset, press
OK
again, to cancel
the
RESET
press any other key.
Default Values
• Working mode: OFF
• Comfort Temp : 19ºC
• Economy Temp : 17ºC
• Frost Protection Temp : 5ºC
• Manual Mode Temp: 19ºC
• T
emperature Compensation: 0ºC
• No RF paired network
• Temperature units ºC
• Control type: PID
• Default Programme: All Economy
• Open Window detection OFF.