Ducasa Vitro-i 1200 Black Скачать руководство пользователя страница 10

10

11

Firmware Version (C4)

It  shows  internal  software  installed  in  the 

electronics.

Open Window detection (C5)

In order to save energy, if a window opens and 

causes a sudden drop in temperature the Vitro-i 

will stop heating.

By default this function is deactivated. To change 

the status of the function, press the +,- button and 

then press ok to confirm.

This  function  detects  a  temperature  drop  of 

0.6ºC every minute over a period 4 minutes.

If the heater is heating, it will be disconnected 

for 30 minutes and shows the Open Window icon 

on the display.

The Vitro-i heater will restore normal function in 

any of these situations:

•  After 30 minutes

•  Increase of 0.2ºC by minute from the point  

of activation.

•  Pressing any key on the Vitro-i Heater

 

 

Heater Reset

Resetting the heater will return all settings to the 

factory defaults and will also delete any “pairing” 

with  a 

  Gateway.  To  activate 

the RESET feature press the 

OK

 button and the 

CONFIG

  button  for  10  seconds.  The  following 

screen will appear:

To confirm the reset, press 

OK

 again, to cancel 

the 

RESET

 press any other key.

Default Values

•  Working mode: OFF

•  Comfort Temp : 19ºC

•  Economy Temp : 17ºC

•  Frost Protection Temp : 5ºC

•  Manual Mode Temp: 19ºC

•  T

emperature Compensation: 0ºC

•  No RF paired network

•  Temperature units ºC

•  Control type: PID

•  Default Programme: All Economy

•  Open Window detection OFF.

Содержание Vitro-i 1200 Black

Страница 1: ...her reference Models Vitro i 750 Black Vitro i 1200 Black Vitro i 1600 Black Vitro i 750 White Vitro i 1200 White Vitro i 1600 White NOTE A qualified electrician must carry out the electrical installa...

Страница 2: ...2...

Страница 3: ...heater becoming hot it must not be positioned directly against or below infammable surfaces Do not dry clothes or towels on the heater nor leave fabrics magazines spray cans volatile substances or si...

Страница 4: ...4...

Страница 5: ...floor According to regulations the apparatus must be connected to the power supply by means of an all pole circuit breaker with a contact gap of at least 3mm or by a thermal magnetic circuit breaker...

Страница 6: ...n the lower slotted holes and mark through the upper slotted holes for the top fixing screws See Figure 3b Drill and plug for these screws In this manner the Vitro i heater will be mounted on the wall...

Страница 7: ...screen will be blank and the heater will lose connection with the Gateway Stand by function Press the Mode OK button until the symbol is present as shown in the following screen When the heater is in...

Страница 8: ...nd then select the minutes and confirm pressing OK once more If a heater is paired with a Gateway time setting is not required as it recognises the system s time automatically Manual Programming Setti...

Страница 9: ...ignored and Lock will be displayed on the screen To unlock keyboard once again press and hold and for 3 seconds until the word Lock disappears When the keypad is locked the heater will still receive...

Страница 10: ...will restore normal function in any of these situations After 30 minutes Increase of 0 2 C by minute from the point of activation Pressing any key on the Vitro i Heater Heater Reset Resetting the heat...

Страница 11: ...11...

Страница 12: ...nce please contact your supplier Waste Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This marking shown on the product...

Отзывы: