Functional Description
61
3.12
RS232/RS422/RS485
Table 22.
Connector types – RS232/RS422/RS485 (9-pin D-Sub)
Table 23.
Pin assignment – RS232/RS422/RS485 (9-pin D-Sub)
Table 24.
Signal mnemonics – RS232
Table 25.
Signal mnemonics – RS422/RS485
Note: Termination resistors between the differential data lines are not equipped.
Connector
Type
On MC50M 9-pin D-Sub plug
e.g., Assmann A-D-S-09-A/KG-LP
Mating
9-pin D-Sub receptacle
e.g., Assmann A-D-F-09-A/KG-LP
Tightening torque: max. 0.6 Nm
RS232
RS422
RS485
1
-
RX+
-
2
RXD
-
-
3
TXD
-
-
4
-
TX/RX+
TX/RX+
5
GND
GND
GND
6
-
RX-
-
7
RTS#
-
-
8
CTS#
-
-
9
-
TX/RX-
TX/RX-
Signal
Direction
Function
GND
-
Signal ground
CTS#
in
Clear to send
RTS#
out
Request to send
RXD
in
Receive data
TXD
out
Transmit data
Signal
Direction
Description
GND
-
Signal ground
RX+/-
in
Receive data lines
TX+/-
out
Transmit data lines
5
9
1
6