Product Overview
19
EMC emission
-
EN 50121-3-2:2016
-
Regelung Nr. EMV 06 :2014-07-29, Anhang E: Messung an Geräten
EMC immunity: EN 50121-3-2:2016
Protective coatings: EN 50155:2017, class PC2 (Any PCB protected on both sides)
Useful life: 20 years (EN 50155:2017, class L4)
Product Compliance: Rail - Wayside Non-Safety Related
Operating temperature: -40 °C to +70 °C (EN 50125-3:2003, class T2, cubicle, with
class T2 maximum extended by 5 °C)
Storage temperature: -40 °C (EN 60068-2-1:2007, Ab) to +85 °C
(EN 60068-2-2:2007, Bb)
Altitude: +3000 m max. (EN 50125-3:2003, class AX)
Humidity: 100 % RH max. (EN 50125-2:2002, control cabinet, class T1/T2/TX)
Shock: 11 ms @ 20 m/s² (EN 50125-3:2003, in a switch cabinet 1 m to 3 m from the
track)
Vibration: 2.3 m/s² (EN 50125-3:2003, in a switch cabinet 1 m to 3 m from the track)
Electrical safety
-
EN 50124-1:2017
-
EN 62368-1:2014 + AC:2015
EMC emission
-
EN 50121-4:2016
-
EN 61000-6-4:2007 + A1:2011
EMC immunity
-
EN 50121-4:2016
-
EN 61000-6-2:2005
Restrictions: Service interfaces may only be used with a maximum cable length of
3 m for installations 10 m or less away from the track.
Product Compliance: Road Vehicle
EMC emission: ECE R10 Rev.5
EMC immunity: ECE R10 Rev.5
Reliability
421 000 h predicted @ 40 °C according to IEC/TR 62380 (RDF 2000)
BIOS/Boot Loader
AMI Aptio UEFI Firmware