background image

3

1) Registering remote control to receivers memory

2) Easy remote control registering

3) Simple remote control removing

4) Output (C1/C2) mode change to

or

.

5) Output (C1/C2) mode change to

bistable

momentary

monostable

Registering remote control do receivers memory is adding particular button with simulataneously assing recivers

output.

It is possible to assing few of buttons to the same channel or to assing remote control button to both of channels.

To remove programmed button, it is necessary to delete remote control from receiver's memory, and assing buttons in right

confriguration (point 3).

Button registering

(C1/C2)

Remarks!

C1/C2

Remarks!

Remarks!

Output's factory settings:

C1 output working mode

monostable (0,5s)

C2 output working mode

monostable (0,5s)

(C1/C2)

MOM

BIST

MONO

(C1/C2)

MONO

Remarks!

C1/C2

MONO

While pushing output button

push choosen remote control's button. LED diode will light.

If pushing output button

stops before pushing transmitter's button receiver will turn on output

programming mode. To exit push shortly other channel button.

It is possible to register new remote control without using receiver's buttons. New remote control must be in radio

range of receiver and previously registered remote control presence is necessary. Easy remote control registering is
unavailable if output is on momentary mode.

a) push and hold for 15 sec. any button of previously registered remote
b) within 3 sec. after releasing the previous button push and hold for 15 sec. any button of new remote control
c) new remote control is registered with same as previous remote configuration.

Failure in registering may be caused by radio interferences, low batteries or lock of easy remote registering

function.

To remove single remote control from receiver's memory push and hold simulataneously output buttons (C1 and

C2). All of LED diodes (except for green LED diode) will light. During lighting push any remote control's button that you want
to remove. Diodes will wane, remote will be removed from receiver's memory.

If you hold the receiver's C1 and C2 buttons for too long, receiver's memory will format.

For monostable mode check point 5.

To change mode of C1 or C2 output push and release chosen output button. Red LED diode will light

.

Yellow LED diode shows actual output mode. Push output button several times to set working mode. Yellow LED diode with

sing for momentary mode,

sing – bistable mode,

sing – monostable mode (check point 5.) To approve

chosen mode push and hold output button (C1/C2). Red LED diode will light and wane. Working mode is registered.

To change output mode to monostable push and release button

, red LED diode will light and yellow LED

diode which shows actual output mode will light. Push output button to set working mode on monostable, signalized by
yellow LED diode with

sing. To approve push and hold edited output button (C1/C2). LED diode with MONO sing will

fade, than start to blink. Hold output button for wanted turn on time in seconds. Number of blinking set turn on time in seconds
(or minutes if after releasing in short time button is being pushed for second again.)

To set turn on time 0,5s release

button before yellow diode with

sing light.

Содержание ZSP Rival 432

Страница 1: ...o enhance radio range use outdoor aerial Outdoor aerial s concentric cable need to be switched toYmarked terminal block and ground marked terminal block 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Rival 432 receiver is one of remote control and access control devices that build ZSP System Basic application of ZSP System is to work with controllers of gate rollers also lightning alarm system direct connection to a...

Страница 2: ...trolock electric connection 3 4 5 1 2 6 7 8 39 mm 102 mm Turn on signalling Working mode signallin during programming momentary monostable bistable Power signalling channel 1 channel 2 Programming buttons shield antenna s u p p l y 1 2 V 2 4 V A C D C channel 1 channel 2 o u t p u t 1 o u t p u t 2 electrolock 24V gate controller manual control output STEP BY STEP supply 24V AC DC Rival 432 receiv...

Страница 3: ...tton of new remote control c new remote control is registered with same as previous remote configuration Failure in registering may be caused by radio interferences low batteries or lock of easy remote registering function To remove single remote control from receiver s memory push and hold simulataneously output buttons C1 and C2 All of LED diodes except for green LED diode will light During ligh...

Страница 4: ...33 92 Mhz TIP 1 mW NEO 3 mW working temperature from 0 C to 55 C 2 1 3 4 2 3 4 1 2 2 1 2 1 2 fig 3 TIP and NEO remotes with buttons 7 Receiver s memory formating To format receiver s memory push and hold simultaneously C1 and C2 buttons All LED diodes except green diode will blink Release buttons when LED diodes stop blink after about 15 seconds Receiver s memory has been formated Remarks Format i...

Отзывы: