To set the controller operation mode:
brie
fl
y press theC2 button, two CL SBS will light up
by brie
fl
y pressing theC2 button, set the desired mode
momentary mode -
LEDs are on
OP +CL
continuous mode -
LEDs are on
STOP +SBS
con
fi
rm the selected mode by pressing the C2 button longer, the LEDs will blink three times indicating
success of the operation.
10.Control via button.The function of unequivocal opening and closing.
The function gives you the ability to control a roller shutter or a group of roller shutters using one button.
It is only available using theSTEP BYSTEP manual control input.
Pressing and holding the button for between 4 and 8 seconds will start closing, regardless of whether the
roller shutter is closed or open.
Pressing and holding the button for longer than 8 seconds will start closing, regardless of whether the
roller shutter is closed or open.
The unequivocal opening and closing function works in both modes (momentary and continuous).
1
4
2
5
3
6
PRESS C2
OP+CL
MOMENTARY MODE
OP+CL OR STOP+SBS
LIGHT UP
STOP+SBS
CONTINUOUS MODE
BRIEFLY PRESS C2
TO CHOOSE MODE
CONFIRM BY PRESSING
C2
LONGER
Fig.10
Setting the momentary / continuous operation mode of the controller.
EN