CONTROLLER INSTALLATION
IMPORTANT REMINDER !!!
Electrical installations must be carried out by experienced and quali
fi
ed personnel
in accordance with applicable law. The device has a dangerous voltage of 230V
50Hz, all connections must be made with the power o
ff
. The installer's task is to
mount the system securely to exclude any risks associated with its use.The person
who installs the device without complying with all applicable laws is responsible
for any damages that the device may cause.
The controller is intended for installation inside installation boxes.
Do not mount the controller in places exposed to high humidity and frequent and sudden
temperature changes. Due to the screw connection accessible from the outside, galvanic
isolation from other devices and wires must be ensured.An example of an electrical connection is
shown in Figures 2 and 3.
Before installing the controller, prepare a place for the controller with power, motor, and optional
manual control buttons connected.
The roller shutter drive should be connected to theOPEN,CLOSE, andCOM terminals.
The button or buttons for manual operation must be connected as required (see Figures 2 and 3).
If you have only one button, you can use the STEP-BY-STEP control by bridging the SO and SC
control inputs.
The connection of the 230V power supply is signaled by the lighting of the PWR diode. A wire
antenna is connected to theANT terminal at the factory.
L
N
230V AC
OP
CL
SO
N
C
SC
L
L
N
230V AC
OP
CL
SO
N
C
SC
L
OP
CL
Fig.2
Example connection diagram
of a roller shutter controller with 2 buttons
open / close.
Fig.3
Example connection diagram
of a roller shutter controller with 1 button
open / stop / close.
SBS