5.2.RADIO RECEIVERS TAB

The RADIO RECEIVERS tab allows you to manage remote control memory files.

Description of buttons and functions of the RADIO RECEIVERS tab

   

opens a folder with local files

 

 

creates a new empty remote controls memory file

 

 

saves the file to a given location on your computer

 

 

allows you to save the file in FLEX .cfbi file format

 

 

allows you to save the file in .csv format

 

 

launches the file editing window

 

 

deletes selected files

 

 

creates a quick copy of the selected file

 

 

allows you to change the file name and description

 

 

displays information about the operations from the log.txt file

 

 

allows to set the default file used by MEMO to write to the receiver 

when the WRITE function is used

15

Fig. 6.

 Main window view - RADIO RECEIVERS tab.

Содержание MEMO

Страница 1: ...SERVICE PROGRAMMER MEMO user manual MEMO PROGRAMMER SOFTWARE MEMO MANAGER v1 1 user manual v1 1 automation systems ...

Страница 2: ...numbers write to receiver 5 4 4 Receiver software update 7 5 Registration of operations 8 6 MEMO code table 9 II MEMO MANAGER MEMO SOFTWARE 10 1 Usage 10 2 Hardware requirements 10 3 Installation and start up 10 4 Connecting MEMO to a computer 10 5 Program main window 10 5 1 CONTROL GSM tab 12 5 1 1 Editing numbers and receiver configuration 13 5 2 RADIO RECEIVERS tab 15 5 2 1 Editing remote contr...

Страница 3: ... telephone numbers to the receiver memory from a file and updatethereceiverfirmware 2 TECHNICAL DATA power supply 3 3 5V via USB or receiver storage capacity 2 MB external dimensions of the housing 75x45x15 mm 3 ELEMENTS OFTHE PROGRAMMER 3 MicroUSB SOCKET for powering the device communication with PC and receiver BACKUP LED green WRITE LED red UPDATE LED orange BACKUP button WRITE button UPDATE bu...

Страница 4: ...ash cyclically to indicate the error code seesection6 The backup file with memory of remote controls receiver numbers is saved in the MEMO programmer It gets the name RD_xxxxx RRF where xxxxx is the file s serial number Each subsequent saved remote controls number memory file will receive a name with the next number The files can be edited after connecting the MEMO programmer to the computer in th...

Страница 5: ... diode will flash cyclically to indicate the error code seeitem6 The remotes numbers from the receiver s memory will be replaced with remotes numbers enteredfromthefile The process of writing remote controls numbers to the receiver is preceded by creating an emergency backup called AUTOBACK RRF Creating an emergency backup does not affect the remote memory storageprocess If errors appear during ba...

Страница 6: ...will first create an emergency backupof the receiver smemory It is signaledbya fast pulsing of the greenBACKUP diodeand lighting of the redWRITE diode Then the process of saving the remote controls to the receiver s memory will start This is indicated by the green BACKUP diode going off and the red WRITE diode pulsing The end of the recordingissignaledbytheblinkingoftheBACKUP WRITEandUPDATELEDs Wh...

Страница 7: ...red during the update the orangeUPDATE diode will flash periodically to indicate the error code see section 6 Depending on what error the receiver has it can reset and run with the old version of thesoftwareorremaininthesoftwareupdatemode Inthiscase repeatthesoftwareupdateprocess In the software update procedure the MEMO programmer always selects the latest firmware version available on the device...

Страница 8: ...tus typeanderrorcode The report on operations is as follows Device type specifies the device type Firmware version receiver firmware version File name name of the file in the MEMO memory used during the operation File device type the type of device the file is for only for firmware File firmware version file firmware version for firmware files Status additional information about the result of the ...

Страница 9: ...e file corrupt firmware file checksum error internal file system error unable to create directory unable to write data to file full memory brak pliku firmware dla podłączonego odbiornika no firmware files error creating automatic backup autobackup no file for write operation WRITE unable to create name for new file operation BACKUP error while reading remotes numbers incorrect checksum repetition ...

Страница 10: ...g installation follow the program installer s guidelines After installing the software starttheMEMOMANAGERprogramandconnecttheMEMOprogrammer 4 CONNECTINGTHEMEMOPROGRAMMERTOACOMPUTER The programmer should be connected to the computer using the USB cable included in the set The programmer s readiness for operation is signaled by blinking of the BACKUP WRITE and UPDATE LEDs Duringtheconnectionwiththe...

Страница 11: ...ed on the left The local directory is a strictlydefinedlocationwheretheprogramstoresremotecontrolmemoryfilesandfirmwarefiles Ontheright filesstoredintheMEMOprogrammer smemoryaredisplayed Connection of the MEMO programmer and proper communication of the program with a computer is indicatedbythe icon thelackofconnectionisindicatedbythe icon CONTROL GSM TAB RADIO RECEIVERS TAB FIRMWARE TAB FILE COPY ...

Страница 12: ...eiver configuration file saves the file to a location on your computer launches the file editing window deletes selected files creates a quick copy of the selected file allows you to change the file name and description displays information about the operations from the log txt file allows to set the default file used by MEMO to write to the receiver when theWRITE function is used Fig 2 Main windo...

Страница 13: ...bers which will save you the time by entering each number manually To import a CSV file create a new file and enter edit options or edit an existing file In the Subscribers tab press Import subscribers fromCSV file A window will open in which you should select in turn separator character column with description column with phone number and prefix number and thenpressthe Import button Thenumberswil...

Страница 14: ...creating and editing a file for a Control GSM receiver make sure that both the Subscribers and Device settings tabs contain the correct values The receiver stores the data ofnumbermemoryandreceiverconfiguration 14 Fig 5 View of the CONTROL GSM receiver settings edition window ...

Страница 15: ...your computer allows you to save the file in FLEX cfbi file format allows you to save the file in csv format launches the file editing window deletes selected files creates a quick copy of the selected file allows you to change the file name and description displays information about the operations from the log txt file allows to set the default file used by MEMO to write to the receiver when theW...

Страница 16: ...nels changethepositionofremotecontrolsinthememory removes the remote control from the list copies the remote control to the program clipboard copies the remote control to the clipboard and removes it from the list displays the remote control editing window in which you can change the position of the remote control in the memory and configure links between remote control buttons and the receiver ch...

Страница 17: ... remote control buttons and the receiver channels removes the remote control from the list copies the remote control to the program clipboard copies the remote control to the clipboard and removes it from the list button visible when there are remote controls in the clipboard clicking activates the clipboard options adds remotes from the clipboard to the list removes remotes from the clipboard sho...

Страница 18: ...he FIRMWARE tab opens a folder with local files allows you to add a firmware file to the directory from any location specified by the user opens a window from which you can download the selected firmware available on the DTM System servers internet connection required deletes selected files opens a window that allows filtering by file name receiver to which the firmware is dedicated firmware versi...

Страница 19: ...e to the end customer This time is counted according to the producer warranty labels or serial numbers placed on every product Producer obliges himself to repair the device for free if during the warranty period there are problems which come because of his fault Broken device should be supplied on customer s expense to the place of purchase and enclose clear and brief description of the breakage T...