1. Principle of operation.

Photocell includes transmitter and receiver (fig.1).The transmitter emit a coded Irfrared

(IR) signal , invisible to the naked eye. Obstacle appearance (e.g. car) on photocell working area
produces a detection signal on receiver output. Receiver has NC and NO type output contacts.
Photocell is destined to work in gate automation system as external element. Built-in signal
lamps in both, receiver and transmitter, supplied with 24V, fulfill signal function in gate system.

2.Technical data.

Guaranteed range

1-15 m

Power supply of transmitter and receiver

24VAC/DC

Current consumption of transmitter

2x 25 mA

Power supply of signal lamp

24VAC/DC

Current consumtion of signalization lamp

2x 40mA

Working temperature (min. / max.)

-20°C / +55°C

dimensions (szer. x g

łę

b. x wys.)

62x28x100mm

Mounting

surface mounted

, IP54

Output contacts

typu NO i NC

3. Photocell mounting.

For proper funcionality photocell must be mounted coaxial, 40-60 cm off the ground,

receiver and transmitter distance not less than 1 m . Because of photosensitive elements it is
recommended to mount receiver on less sun exposure side. Both receiver and transmitter must
be mounted vertically. Terminal blocks and humidity carrying openings should be in the
bottom part of enclosure. Proper receiver and
transmitter adjustment is

facilitated by

receiver's

diode RX. RX diode lights when

transmitter ray reaches receiver. Both
enclosures should be mounted by 2 (diagonal
mounting) or 4 screws available in set. To scale
down photocell sensitivity (minor receiver and
transmitter distance) it is recommended to
dismount transmitter's lens.

phoyocell

FOCUS / FOCUS FLASH

MOUNTING INSTRUCTION

v.3.0

Fig. 1

Receiver -  transmitter location

DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa
ul. Brzeska 7, 85-145 Bydgoszcz, POLAND
tel./fax. (52) 340-15-83, 340-15-84
www.dtm.pl, [email protected]

transmitter - TX

receiver - RX

RX

POWER

POWER

LED signalling

RX

TX

max 15 m.
min 1 m.

LED signalling

Terminal blocks

Содержание FOCUS

Страница 1: ...ocell must be mounted coaxial 40 60 cm off the ground receiver and transmitter distance not less than 1 m Because of photosensitive elements it is recommendedtomountreceiveronlesssunexposureside Bothreceiverandtransmittermust be mounted vertically Terminal blocks and humidity carrying openings should be in the bottom part of enclosure Proper receiver and transmitter adjustment is facilitated by re...

Страница 2: ...controller Connect power supply to receiver and transmitter When power is on red LED s POWER in receiver and transmitter light Next connectgatecontrollerinputtophotocell sreceiveroutput RXpins 1 2or2 3 Payattention Fig 2 Assembly dimentions scale 1 1 transmitter receiver assembly drawing 72 mm 22 mm 4 3 2 1 DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa ul Brzeska 7 85 145 B...

Страница 3: ... of receiver RX next in the middle of distance between them In all cases photocell should switch from standby to alarm mode which is signalizedbyRXdiodewane CONNECTION SCHEME DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa ul Brzeska 7 85 145 Bydgoszcz POLAND tel fax 52 340 15 83 340 15 84 www dtm pl dtm dtm pl transmitter TX receiver RX signal INPUT photocell NC Peripherial ...

Страница 4: ...dbyimproper usage user self repairs and adaptations lightning strikes over voltages or short circuits in the mainssupply Appropriatelegalactsregulatesdetailsofthewarranty DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa ul Brzeska 7 85 145 Bydgoszcz POLAND tel fax 52 340 15 83 340 15 84 www dtm pl dtm dtm pl phoyocell FOCUS FOCUS FLASH MOUNTING INSTRUCTION The intention of the...

Отзывы: