6.Warranty.

DTM System checks all the devices before shipping. The warranty time is 24 months

from the selling date. This time is counted according to the warranty label. The manufacturer
will fix all the problems which come because of his fault. Non functionaling device should be
delivered back to the distributor with short problem description.The cost of mount/dismount is
covered by user.The warranty do not cover: batteries in the remotes, faults caused by improper
usage, user self repairs and adaptations, lightning strikes, over voltages or short circuits in the
mains supply.Appropriate legal acts regulates details of the warranty.

DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa
ul. Brzeska 7, 85-145 Bydgoszcz, POLAND
tel./fax. (52) 340-15-83, 340-15-84
www.dtm.pl, [email protected]

phoyocell

FOCUS / FOCUS FLASH

MOUNTING INSTRUCTION

The intention of the WEEE Directive (Directive 2002/96/EC on waste electrical and electronic
equipment) is to reduce the amount of hazardous substances in waste.
The underlying purpose is to promote the avoidance, recovery and risk-free disposal of waste.

Содержание FOCUS

Страница 1: ...ocell must be mounted coaxial 40 60 cm off the ground receiver and transmitter distance not less than 1 m Because of photosensitive elements it is recommendedtomountreceiveronlesssunexposureside Bothreceiverandtransmittermust be mounted vertically Terminal blocks and humidity carrying openings should be in the bottom part of enclosure Proper receiver and transmitter adjustment is facilitated by re...

Страница 2: ...controller Connect power supply to receiver and transmitter When power is on red LED s POWER in receiver and transmitter light Next connectgatecontrollerinputtophotocell sreceiveroutput RXpins 1 2or2 3 Payattention Fig 2 Assembly dimentions scale 1 1 transmitter receiver assembly drawing 72 mm 22 mm 4 3 2 1 DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa ul Brzeska 7 85 145 B...

Страница 3: ... of receiver RX next in the middle of distance between them In all cases photocell should switch from standby to alarm mode which is signalizedbyRXdiodewane CONNECTION SCHEME DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa ul Brzeska 7 85 145 Bydgoszcz POLAND tel fax 52 340 15 83 340 15 84 www dtm pl dtm dtm pl transmitter TX receiver RX signal INPUT photocell NC Peripherial ...

Страница 4: ...dbyimproper usage user self repairs and adaptations lightning strikes over voltages or short circuits in the mainssupply Appropriatelegalactsregulatesdetailsofthewarranty DTM System spółka z ograniczoną odpowiedzialnością spółka komandytowa ul Brzeska 7 85 145 Bydgoszcz POLAND tel fax 52 340 15 83 340 15 84 www dtm pl dtm dtm pl phoyocell FOCUS FOCUS FLASH MOUNTING INSTRUCTION The intention of the...

Отзывы: