Yellow Trouble LED

This yellow LED will flash to indicate a trouble on the unit. The number of flashes indicates the type of trouble. See the table
below for the coded flashes and the conditions which will activate the trouble status LED.

Table 5: Yellow Trouble Status LED

# of

Flashes

Trouble

# of

Flashes

Trouble

2

Panel Supervision Trouble

8

Receiver Supervision Trouble

4

Not Applicable

9

FTC Trouble

5

Not Applicable

10

Not Applicable

6

Ethernet Trouble

12

Module Configuration Trouble

7

Receiver Not Available Trouble

NOTE:

Only the highest priority trouble (2 flashes is the highest priority trouble) is indicated. When this trouble is restored, the

next highest trouble will indicate, if present. This will continue until all troubles have been cleared (yellow LED is not
flashing).

Red Network Connection Status LED

BLINKING

: Indicates communications in progress.

l

Once quickly for outgoing Ethernet transmission.

l

Twice quickly to indicate incoming Ethernet ACK/NACK.

OFF

: This is the normal state of the red network connection status LED. There are no network connection issues present.

ON

: There is a problem with the Ethernet or the cellular network connection. LED will be ON if any of the following occur:

l

Ethernet cable is not connected

l

DHCP configuration times out.

Network Activity LED (Red)

l

Ethernet Activity

: Red LED will blink quickly once for transmit, or twice for receive.

Communicator Troubleshooting

Table 6: Trouble Indications

Trouble Indic-

ation

Trouble

Indicator

Digit

Possible

Causes

Trouble Possible Solution

No Indication

N/A

No Power

l

Check the power connections between the panel and the communicator.

l

Confirm PC-LINK cable is properly installed between communicator and panel.

Yellow LED

2 Flashes

02

Panel

Supervision

Trouble

l

Check section [382] toggle option[5] is ON (Alternate Communicator Enabled).

l

Ensure the PC-LINK cable between the panel and communicator is connected
properly (not reversed) and is securely in place.

Yellow LED

6 Flashes

06

Ethernet

Trouble

l

Check with the ISP to confirm Internet service is active in the area.

l

Ensure the Ethernet cable is securely inserted into the RJ45 jack of the
communicator and the hub/router/switch.

l

Check the link light on the hub/router/switch is ON. If link light is OFF, start the
hub/router/switch.

l

If DHCP is used, ensure that the unit has an assigned IP address from the
server. In Section [851] [992] verify a valid IP address is programmed. If not,
contact the network administrator.

l

If problem persists, replace the Ethernet cable and RJ45 connector.

Yellow LED

7 Flashes

07

Receiver Not

Available

l

Ensure that the Ethernet path has Internet connectivity.

l

If using a static IP address, confirm that the gateway and subnet mask are
entered correctly.

l

If the network has a firewall, ensure the network has the programmed

l

outgoing ports open (default UDP port 3060 and port 3065).

l

Ensure that all the receivers are programmed for DHCP or have the proper IP

9

Содержание TL280

Страница 1: ...llation Guide V4 1 For installation manual visit www dsc com Warning This manual contains informationon limitations regarding product use andfunction and inform ationonthelimitations as toliability of...

Страница 2: ...5 TechnicalSpecifications Ratings and Compatibility 5 CommunicatorInstallation Configuration 5 Installing Communicatorin Panel 6 InitialPanelProgramming 8 CommunicatorStatus LEDs 8 CommunicatorTrouble...

Страница 3: ...time to protectthe occupantsortheirbelongings Motion Detectors Motion detectorscan onlydetectmotion within the designated areasasshown in theirrespective installation instructions Theycannotdiscrimina...

Страница 4: ...al apply to all specified models unless stated differently Models ending in R include a built in RS 232 interface for connecting to third party applications The TL280 R supports integration over IP an...

Страница 5: ...unicator Ratings Model TL280 R PowerSupply Ratings InputVoltage 10 8 12 5 VDC Power is supplied from the panel s PC Link header or a PCL 422 module in remote cabinetinstallations In remote cabinet ins...

Страница 6: ...an RS 232 cable must be connected between the third party device and the communicator module NOTE Maximum cable length for RS 232 cable is 8 ft 2 4 m Please refer to the installation manual for the th...

Страница 7: ...or Wiring Diagram AUDIO DEFAULT DSC UA601 PC LINK COM TL280 R ACAC Z1 COM Z2 Z3 COM Z4 Z5 COM Z6 Z7 COM Z8 AUX BELL PGM1 PGM3 RING T 1 HS2016 2032 2064 2128 UA621 Input Ratings 10 8V 12 5 VDC 100mA DS...

Страница 8: ...e Communicator Set up 1 In panel section 377 Communication Variables subsection 002 Communication Delays sub subsection 1 Com munication Delay program 060 seconds 2 In panel section 382 Communicator O...

Страница 9: ...wice for receive Communicator Troubleshooting Table 6 Trouble Indications Trouble Indic ation Trouble Indicator Digit Possible Causes Trouble Possible Solution No Indication N A No Power l Check the p...

Страница 10: ...her N A Initialization Sequence l The unitis still initializing please waitwhile the unitgets its programming and establishes a connection to all programmed receivers NOTE This process may take severa...

Страница 11: ...011 Installer Code Default CAFE Valid range 0000 FFFF 012 DLS Incoming Port Default 0BF6 3062 Valid range 0000 FFFF 013 DLS Outgoing Port Default 0BFA 3066 Valid range 0000 FFFF 015 DLS Call Up IP De...

Страница 12: ...eceiver 1 Domain Name Default 32 ASCIIcharacters ________________________________ Ethernet Receiver 2 Options 111 Ethernet Receiver 2 Account Code Default 0000000000 Valid range 0000000001 FFFFFFFFFE...

Страница 13: ...orworkmanship such written notice to be received in alleventspriorto expir ation ofthe warrantyperiod There isabsolutelyno warrantyon software and all software productsare sold asa userlicense underth...

Страница 14: ...torcontract IfYou do notagree to the termsofthisEULA DSC is unwilling to license the SOFTWAREPRODUCTto You and You have no rightto use it SOFTWARE PRODUCT LICENSE The SOFTWAREPRODUCTisprotected bycopy...

Страница 15: ...andardsEN61000 6 3 EN55022 CISPR22 4 The TL280R TL280 module usesAES128 encryption and heartbeatsuper vision forboth the Ethernetcommunication path and itmeetssecuritylevelsS2 as perEN50136 2 1 EN5013...

Страница 16: ...yco willaggressivelyenforce itsintellectualpropertyrightsto the fullestextentofthe law including pursuitofcriminalprosecution wherevernecessary All trademarksnotowned byTyco are the propertyoftheirres...

Отзывы: