Trouble Indic-

ation

Trouble

Indicator

Digit

Possible

Causes

Trouble Possible Solution

address and port number.

Yellow LED

8 Flashes

08

Receiver

Supervision

Trouble

l

This trouble is indicated when supervision is enabled and the unit is not able to
successfully communicate with the receiver.

l

If this trouble persists, contact the central station.

Yellow LED -

9 Flashes

09

FTC Trouble

l

The unit has exhausted all communications attempts to all programmed
receivers for events generated by the communicator.

l

Restart the system, if trouble persists, contact the dealer.

Yellow LED

12 Flashes

0C

Module

Configuration

Trouble

l

This indication appears when section [021] system account code or sections
[101] or [111] receiver account code have not been programmed. Ensure that a
valid account code has been entered in these sections.

Red and

Yellow LEDs

flashing
together

N/A

Initialization

Sequence

l

The unit is still initializing please wait while the unit gets its programming and
establishes a connection to all programmed receivers.

NOTE: This process may take several minutes to complete.

Boot Loader

Failed

l

If the initialization sequence is taking more than several minutes, the boot loader
might have failed.

l

Confirm that the boot loader has failed by entering communicator programming
[*][8][installer code][851].

l

If access is granted, continue waiting for the initialization sequence to complete.

l

If access is denied (long error tone), disconnect power from, then reconnect
power to the communicator module.

.

Ethernet Programming Options

The programming sections described in this document can be viewed at the keypad LCD. To start programming enter: [*][8]
[installer code][851][section number], where section number is the 3-digit section number referenced in this section. The pro-
gramming worksheets at the end of this document can be used to record the new values when programming changes have
been made from the default values.

10

Содержание TL280

Страница 1: ...llation Guide V4 1 For installation manual visit www dsc com Warning This manual contains informationon limitations regarding product use andfunction and inform ationonthelimitations as toliability of...

Страница 2: ...5 TechnicalSpecifications Ratings and Compatibility 5 CommunicatorInstallation Configuration 5 Installing Communicatorin Panel 6 InitialPanelProgramming 8 CommunicatorStatus LEDs 8 CommunicatorTrouble...

Страница 3: ...time to protectthe occupantsortheirbelongings Motion Detectors Motion detectorscan onlydetectmotion within the designated areasasshown in theirrespective installation instructions Theycannotdiscrimina...

Страница 4: ...al apply to all specified models unless stated differently Models ending in R include a built in RS 232 interface for connecting to third party applications The TL280 R supports integration over IP an...

Страница 5: ...unicator Ratings Model TL280 R PowerSupply Ratings InputVoltage 10 8 12 5 VDC Power is supplied from the panel s PC Link header or a PCL 422 module in remote cabinetinstallations In remote cabinet ins...

Страница 6: ...an RS 232 cable must be connected between the third party device and the communicator module NOTE Maximum cable length for RS 232 cable is 8 ft 2 4 m Please refer to the installation manual for the th...

Страница 7: ...or Wiring Diagram AUDIO DEFAULT DSC UA601 PC LINK COM TL280 R ACAC Z1 COM Z2 Z3 COM Z4 Z5 COM Z6 Z7 COM Z8 AUX BELL PGM1 PGM3 RING T 1 HS2016 2032 2064 2128 UA621 Input Ratings 10 8V 12 5 VDC 100mA DS...

Страница 8: ...e Communicator Set up 1 In panel section 377 Communication Variables subsection 002 Communication Delays sub subsection 1 Com munication Delay program 060 seconds 2 In panel section 382 Communicator O...

Страница 9: ...wice for receive Communicator Troubleshooting Table 6 Trouble Indications Trouble Indic ation Trouble Indicator Digit Possible Causes Trouble Possible Solution No Indication N A No Power l Check the p...

Страница 10: ...her N A Initialization Sequence l The unitis still initializing please waitwhile the unitgets its programming and establishes a connection to all programmed receivers NOTE This process may take severa...

Страница 11: ...011 Installer Code Default CAFE Valid range 0000 FFFF 012 DLS Incoming Port Default 0BF6 3062 Valid range 0000 FFFF 013 DLS Outgoing Port Default 0BFA 3066 Valid range 0000 FFFF 015 DLS Call Up IP De...

Страница 12: ...eceiver 1 Domain Name Default 32 ASCIIcharacters ________________________________ Ethernet Receiver 2 Options 111 Ethernet Receiver 2 Account Code Default 0000000000 Valid range 0000000001 FFFFFFFFFE...

Страница 13: ...orworkmanship such written notice to be received in alleventspriorto expir ation ofthe warrantyperiod There isabsolutelyno warrantyon software and all software productsare sold asa userlicense underth...

Страница 14: ...torcontract IfYou do notagree to the termsofthisEULA DSC is unwilling to license the SOFTWAREPRODUCTto You and You have no rightto use it SOFTWARE PRODUCT LICENSE The SOFTWAREPRODUCTisprotected bycopy...

Страница 15: ...andardsEN61000 6 3 EN55022 CISPR22 4 The TL280R TL280 module usesAES128 encryption and heartbeatsuper vision forboth the Ethernetcommunication path and itmeetssecuritylevelsS2 as perEN50136 2 1 EN5013...

Страница 16: ...yco willaggressivelyenforce itsintellectualpropertyrightsto the fullestextentofthe law including pursuitofcriminalprosecution wherevernecessary All trademarksnotowned byTyco are the propertyoftheirres...

Отзывы: