Figure 2: HS2016/2032/2064/2128 Control Panel
PC-Link cable connector
screw
GSM Radio
RJ-45
U
A601
HS2016/2032/2064/2128
WARNING! - Modules are power limited. Do not route any wiring over the circuit board. Maintain at least 1in. (25.4mm)
separation between circuit board and wiring. A minimum of ¼ in. (7mm) separation must be maintained at all points
between non-power limited wiring and power limited wiring.
3. To electrically connect the communicator to the panel, perform the following steps (See
Figure 3
).
a. Disconnect both AC power and battery connections from the panel, and disconnect telephone line.
Figure 3: Communicator Wiring Diagram
AUDIO/DEFAULT
DSC
UA601
PC-LINK
COM
TL280(R)
AC
AC
Z1 COM Z2 Z3 COM Z4 Z5 COM Z6 Z7 COM Z8
AUX+
B
EL
L
+
PGM1 PGM3
RING
T-1
HS2016/2032/2064/2128
UA621
Input Ratings:
+10.8V ~ +12.5 VDC
100mA
DSC Panel min. power requirements:
- 16.5 VAC 40 VA transformer;
- 12 VDC 7Ah battery
Jumper pins 4 and 5
to reset.
1
From NID
Use only CAT5
Supervised
RJ-45
G
R
N
YEL
TIP
R-1
B
L
K
R
E
D
A
U
X
-
B
EL
L
-
EG
N
D
T
X+
G
N
D
T
X-
R
X+
R
X-
SH
LD
Network Link
YELLOW
PGM2 PGM4
Maximum cable length
100 m (328 ft)
PCLINK_2
Red
Red
RS-232
To
3rd
party device
4. Install the RS-323 connections (R models only). If using the communicator with a third party device, wire the connections
as per the table below. Maximum cable length for RS-232 cable is 8 ft. (2.4 m).
NOTE:
Please refer to the installation manual for the third party device for wiring instructions.