[074] Key Options

[076] First Keypad Options

[077] Second Keypad Options

[080] PGM Terminal 1

Default: 01  

 

I_______I _______I 

   

 

1-14 Follow PGM Output Number, 15 Local PGM Pulse , 16 Local PGM Toggle

[082] Local PGM Output Pulse Activation Time

Default: 00  

 

I_______I _______I 

   

Minutes (Valid Range 00-99)

Default: 05  

 

I_______I _______I 

   

Seconds (Valid Range 00-99)

[101]-[108] Partition Labels

 

(PK5500\RFK5500 Only)

ex. For Partition 1 enter section [101], for Partition 2 enter section [102] etc.

NOTE: Partition 1 Label is also used as the System Label

[120]-[151] Command Output Labels

 

Default: “Command_O/P_1” - “Command_O/P_4”

[201]-[264] Door Chime Sound Programming

You can program the keypad to make up to four different door chime sounds for individual zones.

ex. For Zone 1 enter section [201], for Zone 2 enter section [202] etc.

[994][Q] Initiate Global Keypad Chime Broadcast

[995][

4

] Reset Keypad Options to Factory Default

[996][

4

] Label Default

[997]  View Software Version 

[998][

4

] Initiate Global Label Broadcast 

[999][

4

] Reset Keypad EEPROM to Factory Defaults

Keypad Display Symbols

Default

Option

ON

OFF

ON

I____I

1 [F]ire Key Enabled

[F]ire Key Disabled

ON

I____I

2 [A]uxiliary Key Enabled

[A]uxiliary Key Disabled

ON

I____I

3 [P]anic Key Enabled

[P]anic Key Disabled

OFF

I____I

4-8 For Future Use

Default

Option

ON

OFF

ON

I____I

1 Display Code when Programming

Display “Xs” when Programming

ON

I____I

2 Local Clock Display ON

Local Clock Display OFF

OFF

I____I

3 Local Clock Displays 24-hr Time

Local Clock Displays AM/PM

ON

I____I

4 Auto Alarm Memory Scroll Enabled

Auto Alarm Memory Scroll Disabled

OFF

I____I

5 Local Display of Temperature ON

Local Display of Temperature OFF

ON

I____I

6 Bypass Options prompt ON

Bypass Options prompt OFF

OFF

I____I

7 For  Future  Use

OFF

I____I

8 Auto-Scroll Open Zones ON

Auto-Scroll Open Zones OFF

Default

Option

ON

OFF

ON

I____I

1 Chime Enabled for Zone Openings

Chime Disabled for Zone Openings

ON

I____I

2 Chime Enabled for Zone Closings

Chime Disabled for Zone Closings

OFF

I____I

3 5th Terminal is Keypad PGM Output

5th Terminal is Keypad Zone Input

ON

I____I

4 Language Selection Enabled

Language Selection Disabled

OFF

I____I

5 Power LED Enabled

Power LED Disabled

ON

I____I

6 Power LED indicates AC present

Power LED indicates AC absent

ON

I____I

7 Alarms always Displayed When Armed

Alarms not Displayed When Armed

OFF

I____I

8 Low Temperature Warning Enabled

Low Temperature Warning Disabled

Section

Partition

Label

[101] to [108] 1 to 8

I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I

I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I

For Partition 1 Command O/P 1 to 4 enter [120] to [123] For Partition 5 Command O/P 1 to 4 enter [136] to [139]
For Partition 2 Command O/P 1 to 4 enter [124] to [127] For Partition 6 Command O/P 1 to 4 enter [140] to [143]
For Partition 3 Command O/P 1 to 4 enter [128] to [131] For Partition 7 Command O/P 1 to 4 enter [144] to [147]
For Partition 4 Command O/P 1 to 4 enter [132] to [135] For Partition 8 Command O/P 1 to 4 enter [148] to [151]

Section Part Cmd.

Output

Label

[120]-[151]1to8 1to4

I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I

I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I

Default

Option

ON

OFF

ON

I____I

1 6 Beeps

Disabled

OFF

I____I

2 “Bing-Bing” Sound

Disabled

OFF

I____I

3 “Ding-Dong” Sound

Disabled

OFF

I____I

4 Alarm  Tone

Disabled

OFF

I____I

5-8 For Future Use

8

Bypass –  Indicates that there are zones automatically or 

manually bypassed.

9

For Future Use

10

Arm Mode – Indicates the mode the panel is armed in.

Stay – Indicates that the panel is armed in the Stay 

Mode. It will turn on at the beginning of the Exit 

Delay

1

Fire –  Indicates that there are fire alarms in memory.

2

Memory –  Indicates that there are alarms in memory.

Away – Indicates that the panel is armed in the Away 

Mode. It will turn on at the beginning of the Exit 

Delay

3

Ready Light (green) –  If the Ready light is on, the system 

is ready for arming.

4

Armed Light (red) –  If the Armed light is on, the system 

has been armed successfully.

11 Chime – This icon turns on when Door Chime is enabled on 

the system and will turn off when Door Chime is disabled.

5

System Trouble –  Indicates that a system trouble is active.

12

Open – When zones are opened, this icon will turn on, and 

7 segment displays 1 and 2 will scroll through the open 

zones.

6

AC –  Indicates that AC is present at the main panel.

7

Program – Indicates that the system is in Installer’s Pro-

gramming, or the keypad is busy.

1

2

3

4
5

6

7

8

1

2

9

10

11

12

7

8

Содержание PowerSeries RFK5500

Страница 1: ...which this equipment is intended to be used ATENCI N Consulte el Manual de instalaci n del sistema para obener informaci n sobre las limitaciones del uso y funciones del producto as como las limitacio...

Страница 2: ...ow access for wiring Mount and Wire Keypad 1 Secure Keypad to wall using mounting holes Use all 4 screws provided unless mounting on a single gang box 2 Place keypad into hooks on the backplate and sw...

Страница 3: ...lted in slot 8 If LCD keypads are used one LCD keypad must remain in slot 8 NOTE The keypad enrolls as two modules Light 1 keypad section Light 17 receiver section NOTE Deleting all wireless devices f...

Страница 4: ...e back up copy solely for archival purposes Except as expressly provided in this EULA You may not otherwise make copies of the SOFTWARE PRODUCT including the printed materials accompanying the SOFTWAR...

Страница 5: ...ass Recall 32 Partition 8 Select 07 System Test 15 Global Stay Arm 24 Bypass Group Recall 33 Local PGM Activate Available only on the PC1616 PC1832 PC1864 version 4 2 or higher Section Zone Label 001...

Страница 6: ...rms always Displayed When Armed Alarms not Displayed When Armed OFF I____I 8 Low Temperature Warning Enabled Low Temperature Warning Disabled Section Partition Label 101 to 108 1 to 8 I_____I__ ___I__...

Страница 7: ...to the backplate The tamper is restored and the zone sends a battery trouble restoral signal to the receiver The battery trouble is now clear and the device should function normally NOTE When batteri...

Страница 8: ...13 I __ _ __ I __ __ _ I_ __ _ _I _ __ __ I __ _ __ I_ _ __ _ I 46 Key 6 I __ _ __ I __ __ _ I_ _ __ _I _ __ _ _I __ _ __ I __ __ _ I 54 Key 14 I __ _ __ I __ __ _ I_ __ _ _I _ __ __ I __ _ __ I_ _ __...

Страница 9: ...en un lugar accesible para los puntos des ignados de entrada y salida Una vez seleccionada una ubicaci n seca y segura lleve a cabo los siguientes pasos para montar el teclado Desmontaje del teclado...

Страница 10: ...ente Si hay m s de un teclado LCD presente en el sistema las etiquetas programadas en un teclado pueden ser difundidas a todo el resto de teclados LCD Lleve a cabo el siguiente procedimiento para tran...

Страница 11: ...avisos de puerta puede ser difundida a todos los dem s teclados Lleve a cabo los siguientes pasos para difundir los avisos de puerta Paso1 Programe un teclado compl etamente Paso2 Aseg rese de que tod...

Страница 12: ...ODUCTO DE SOFTWARE se licencia como un producto nico Sus partes componentes no pueden ser separadas para el uso en m s de una unidad de HARDWARE c Producto NICO INTEGRADO Si usted adquiri este SOFTWAR...

Страница 13: ...Estas caracter sticas est n disponibles s lo en el PC1616 PC1832 PC1864 la versi n 4 2 o m s alto solo Secci n Zona Etiqueta 001 064 1 64 I _ _ _ _ _ I _ _ _ _ _ I _ _ _ _ _ I _ _ _ _ _ I _ _ _ _ _ I...

Страница 14: ...cla de p nico P desactivada OFF I____I 4 8 Para uso futuro Predefinido Opci n ON OFF ON I____I 1 Mostrar el c digo durante la pro gramaci n Mostrar Xs durante la programaci n ON I____I 2 Visualizaci n...

Страница 15: ...or indicando la resoluci n del problema de la bater a El problema de la bater a estar resuelto y el dispositivo deber funcionar normalmente NOTA Cuando tengan que sustituirse las bater as de un dispos...

Страница 16: ...__ __I 56 Tecla 16 I_____ I_____I_____I__ ___I_____I____ _I Funci n1 predef 03 Funci n2 predef 04 Funci n3 predef 27 Funci n4 predef 30 Funci n1 predef 03 Funci n2 predef 04 Funci n3 predef 27 Funci n...