![DSC Power608 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/dsc/power608/power608_installation-manual_2534729035.webp)
P r o g r a m m i n g W o r k s h e e t s
31
[016] Fourth System Option Code
Default Option
ON
Off
Section
Page
#
ON
I________I
1
AC Trouble Displayed
AC Trouble Not Displayed
OFF
I________I
2
Trouble Light Flashes if AC Fails
Trouble Light Does Not Follow AC Status
OFF
I________I
3
Blank Keypad When Not Used
Keypad Active Always
OFF
I________I
4
Code Required to Remove Kypd Blanking No Code Required
ON
I________I
5
Keypad Backlighting is enabled
Keypad Backlighting is disabled
OFF
I________I
6
Power Save Mode enabled
Power Save Mode disabled
OFF
I________I
7
Bypass Status Displayed While Armed Bypass Status Not Displayed While Armed
OFF
I________I
8
Keypad Tampers enabled
Keypad Tampers disabled
[017] Fifth System Option Code
Default Option
ON
Off
Section
Page
#
ON
I________I
1
Unident.
Wireless
Key
Disarm
Enabled Disabled
OFF
I________I
2-8
For
future
use
[018] Sixth System Option Code
Default Option
ON
Off
Section
Page
#
OFF
I________I
1
Troubles are Latching
Troubles Follow Restore
OFF
I________I
2
Engineer's Reset Enabled
Engineer's Reset Disabled
OFF
I________I
3
Automatic Battery Check Enabled
Normal Battery Tests Only
OFF
I________I
4
Contact I.D. Partial Close Identifier is 5 Partial Close Identifier is 4
OFF
I________I
5-8
For
future
use
[020] Keypad Zone Assignments
(Section 2.11 “Keypad Zones” on page 6)
NOTE:Only one keypad may be assigned to a zone.
Default
00
I________I_______I
Keypad (address 1) Zone Valid entries are zones 01-08
00
I________I_______I
Keypad (address 2) Zone Valid entries are zones 01-08
00
I________I_______I
Keypad (address 3) Zone Valid entries are zones 01-08
00
I________I_______I
Keypad (address 4) Zone Valid entries are zones 01-08
00
I________I_______I
Keypad (address 5) Zone Valid entries are zones 01-08
00
I________I_______I
Keypad (address 6) Zone Valid entries are zones 01-08
00
I________I_______I
Keypad (address 7) Zone Valid entries are zones 01-08
00
I________I_______I
Keypad (address 8) Zone Valid entries are zones 01-08
[030]Zone Loop Response Options
Default Option
ON
Off
Section
Page
#
OFF
I________I
1
Zone 1 is Fast Loop Response
Zone 1 is Normal Loop Response
OFF
I________I
2
Zone 2 is Fast Loop Response
Zone 2 is Normal Loop Response
OFF
I________I
3
Zone 3 is Fast Loop Response
Zone 3 is Normal Loop Response
OFF
I________I
4
Zone 4 is Fast Loop Response
Zone 4 is Normal Loop Response
OFF
I________I
5
Zone 5 is Fast Loop Response
Zone 5 is Normal Loop Response
OFF
I________I
6
Zone 6 is Fast Loop Response
Zone 6 is Normal Loop Response
OFF
I________I
7-8
For future use
Содержание Power608
Страница 4: ...ii PC5008 Wiring Diagram...
Страница 50: ...46 NOTES...