![DSC Power608 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/dsc/power608/power608_installation-manual_2534729045.webp)
41
Appendix A: Reporting Codes
The following tables contain Contact ID and Automatic SIA for-
mat reporting codes. For more information on reporting code
formats and notes about individual reporting codes, see sec-
tions 5.8
“Communicator – Reporting Codes” on page 17 and
“Communicator – Reporting Formats” on page 18.
Contact ID
The first digit (in parentheses) will automatically be sent by the
control. The second two digits are programmed to indicate
specific information about the signal.
For example, if zone 1 is an entry/exit point, you could pro-
gram the event code as [34]. The central station would
receive the following:
*BURG - ENTRY/EXIT - 1
where the “1” indicates which zone went into alarm.
SIA Format - Level 2 (Hardcoded)
The SIA communication format used in this product follows the
level 2 specifications of the SIA Digital Communication Stan-
dard - January 1996. This format will send the Account Code
along with its data transmission. The transmission would look
similar to the following at the receiver:
N Ri01
BA 01
N
= New
Event
Ri01 = Partition
/Area
Identifier
BA
= Burglary
Alarm
01
=
Zone 1
Section #
Reporting Code
Code Sent When...
Dialer
Direction*
Contact
ID Codes
SIA Auto Rep
Codes**
[320]
Zone Alarms
zone goes into alarm
A/R
(1) 3A
See Table 3
[324]
Zone Restorals
alarm condition has been restored
A/R
(1) 3A
[330]
[334]
Zone
Tamper/Restoral
zone exhibits a tamper condition/tamper condition
restored
T/R
(1) 44
TA-ZZ/TR-ZZ
[328]
Duress Alarm
duress code entered at keypad
A/R
(1) 21
HA-00
[328]
Opening After Alarm
system disarmed with alarm in memory
A/R
(4) A6
OR-00
[328]
Recent Closing
alarm occurs within two minutes of system arming
A/R
(4) 59
CR-00
[328]
Zone Expander Supervisory
Alarm/Rest.
panel loses/restores supervisory transmission over the
Keybus from enrolled PC5132 module or keypads with
zone inputs
A/R
(1) 43
UA-00/UH-00
[328]
Cross Zone (Police Code)
Alarm
two zones on the same partition go into alarm during
any given armed-to-armed period (incl. 24Hr zones)
A/R
(1) 4A
BV-00
[329]
[F] Key Alarm/Rest.
Keypad fire alarm (alarm and restore rep. codes sent
together)
A/R
(1) 15
FA-00/FH-00
[329]
[A] Key Alarm/Rest.
Keypad auxiliary alarm (alarm and restore rep. codes
sent together)
A/R
(1) AA
MA-00/MH-00
[329]
[P] Key Alarm/Rest.
Keypad panic alarm (alarm and restore rep. codes sent
together)
A/R
(1) 2A
PA-00/PH-00
[329]
PGM2 Alarm/Rest.
a panic button wired to PGM2 is pressed / access code
is entered (PGM2 programmed as option [23] or [24])
A/R
(1) 4A
UA-99/UH-99
[338]
General System Tamper/
Rest.
enrolled module with tamper inputs has a tamper alarm/
all module tampers restored
T/R
(1) 45
TA-00/TR-00
[338]
Keypad Lockout
max. number of incorrect access codes has been
entered at a keypad
T/R
(4) 21
JA-00
[339-343]
Closings
system armed (user 01-34, 40-42 indicated)
O/C
(4) A2
CL-UU
[343]
Partial Closing
one or more zones bypassed when system armed
O/C
(4) 7A
CG-ZZ
[343]
Special Closing
Closing (arming) using one of the following methods:
quick arm, auto arm, keyswitch, function key, mainte-
nance code, DLS software
O/C
(4) AA
CL-00
[344-348]
Openings
system disarmed (user 01-34, 40-42 indicated)
O/C
(4) A2
OP-UU
[348]
Auto Arm Cancellation
auto arm cancelled
O/C
(4) A5
CE-00
[348]
Special Opening
Opening (disarming) using one of the following meth-
ods: keyswitch, maintenance code, DLS software
O/C
(4) AA
OP-00
[349-350]
Battery Trouble/Rest.
PC5008 battery is low/battery restored
MA/R
(3) A2
YT-00/YR-00
* A/R = alarms/restorals;T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
** UU = user number (user01-42); ZZ = zone number (01-08)
Содержание Power608
Страница 4: ...ii PC5008 Wiring Diagram...
Страница 50: ...46 NOTES...