P r o g r a m   D e s c r i p t i o n s :  

5 . 2 2   K e y p a d   B l a n k i n g

25

To disable the keypad lockout option, program the Number of
Invalid Codes Before Lockout as [000].

NOTE: If Keypad Lockout is active, the panel CANNOT be
armed / disarmed with a keyswitch.

Keypad Lockout Options . . . . . . . . . . . . . . . . .  Section [012]

5.22 Keypad Blanking

If the 

Blank Keypad When Not in Use

 option is enabled, the

panel will turn off all lights and LCDs on the keypads when no
keys are pressed for 30 seconds. The keys, however, will
remain backlit.
The panel will turn the lights and LCDs back on if entry delay
begins or an audible alarm occurs. The lights and LCDs will
also come on if a key is pressed or, if a valid access code is
entered when the 

Code Required to Restore Blanking

option is enabled.

NOTE:If using a PC5132 v3.0 or greater, and wireless keys, do 
not enable the Code Required to Restore Blanking option, as
the keys will not function correctly.

If the 

Power Save Mode

 option is enabled the panel will blank

all keypad lights including backlighting when AC power fails,
in order to conserve the backup battery.

Blank Keypad when not in use. . . . . . . . . .  Section [016]: [3] 
Code Required to Restore Blanking. . . . . .  Section [016]: [4]
Power Save Mode  . . . . . . . . . . . . . . . . . . .  Section [016]: [6]

5.23 Keypad Backlighting

The keys of all the keypads can be backlit to provide easy
viewing in dim lighting conditions. If the 

Keypad Backlighting

option is enabled the keys will be illuminated.

Keypad Backlighting Option  . . . . . . . . . . .  Section [016]: [5]

5.24 Loop Response

The normal loop response time for all zones is under 400 milli-
seconds. 
Zones 1-6 on the control board, however, can be programmed
for a fast loop response (under 40ms). 

Zones 1-6 are Fast Loop Response . . . . . Section [030]: [1-6]

5.25 Keypad Tampers

If the 

Keypad Tampers Enable

 option is selected, the panel

will display and transmit a 

General System Tamper

 reporting

code if any keypad is removed from the wall. When the key-
pad tamper is restored, the panel will transmit the 

General

System Tamper Restoral

 reporting code. All keypads should

be properly installed and secured before enabling this option.
If the 

All System Tampers Require Installer Reset

 option is

enabled, any system tampers must be reset by entering
[*][8][Installer’s Code] before the system can be armed. Auto-
Arming and Keyswitch arming will also be prevented in the
presence of any system tamper.
The 

Auto Arm Cancellation

 code is not transmitted when a

reset is required because a user has not cancelled the auto
arming sequence.

Keypad Tamper Enable . . . . . . . . . . . . . . .  Section [016]: [8]
General System Tamper and Tamper 
Restoral Reporting Codes  . . . . . . . . . . . . . . . .  Section [338]

System Tampers Req. Installer Reset  . . . . .Section [701]: [4]

NOTE: After enabling keypad tampers, it is recommended to 
tamper and restore all keypads to ensure proper functioning.

5.26 Additional System Modules

The following modules are programmed through the Module
Programming sections [801]-[804]: the PC5400 Printer mod-
ule, the PC59XX Audio Interface module, the Links2X50 Long-
Range Radio interface and the PC5132 Wireless Receiver and
all of its devices. For instructions on the installation and pro-
gramming of these additional modules and devices, please
see their respective installation and programming manuals.

PC5400 Programming . . . . . . . . . . . . . . . . . . . . Section [801]
PC59XX Programming . . . . . . . . . . . . . . . . . . . . Section [802]
LINKS2X50 Programming . . . . . . . . . . . . . . . . . Section [803] 
PC5132 Programming . . . . . . . . . . . . . . . . . . . . Section [804]

5.27 Engineer's Reset 

If the 

Engineer’s Reset 

option is enabled, if the panel has

gone into alarm during the previous armed period, or if a 24
Hour zone has gone into alarm, the system will not be ready to
arm (Ready Light OFF) until:

Installer’s Programming is entered 

Engineer's Reset is performed via Downloading software.

NOTE:This feature applies to Tampers and Faults in both
armed and disarmed states. This does not apply to Module
Tampers, System Supervisories, Zone Expander or PGM2
alarms.

Engineer’s Reset  . . . . . . . . . . . . . . . . . . . . .Section [018]: [2]

5.28 Clock Adjust

In order to compensate for timing inaccuracies, the panel may
be programmed to add or subtract seconds during the last
minute of each day using the 

Clock Adjust

 programming sec-

tion. Valid entries are 01 - 99. The default setting is 60 sec-
onds. To determine the value to be programmed in this
section, monitor the amount of time lost or gained by the panel
over a period of time. Then, calculate the average amount of
time per day that the panel gains or loses. If the clock’s timing
is off, it may be corrected with this setting.

Example #1:

 The clock loses an average of 9 seconds per

day. 

Solution:

 Program the panel to adjust the clock by 51

seconds (instead of the default 60 seconds) for the last minute
of each day in section [700]. This will speed up the panel’s
clock by 9 seconds, correcting the problem.

Example #2:

 The clock gains an average of 11 seconds per

day. 

Solution:

 Program the panel to adjust the clock by 71

seconds (instead of the default 60 seconds) for the last minute
of each day in section [700]. This will slow down the panel’s
clock by 11 seconds, correcting the problem.

NOTE: If the auto-arm time is set for 23:59, any change to the
Clock Adjust option will directly affect the auto-arm pre-alert
time.

Clock Adjust. . . . . . . . . . . . . . . . . . . . . . . . . . . . Section [700]

5.29 Timebase

In cases of unstable AC power input you can use the internal
crystal to keep a more accurate timebase by enabling the

Timebase is Internal Crystal

 option. 

Содержание Power608

Страница 1: ...manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read PC5008...

Страница 2: ...ces or passing traffic Audible warning devices however loud may not be heard by a hearing impaired person Telephone Lines If telephone lines are used to transmit alarms they may be out of service or b...

Страница 3: ...5 Program Descriptions 14 5 1 Programming Security Codes 14 5 2 Zone Programming 14 5 3 Zone Attributes 15 5 4 Assigning Keypad Zones 16 5 5 Communicator Dialing 16 5 6 Communicator Account Numbers 17...

Страница 4: ...ii PC5008 Wiring Diagram...

Страница 5: ...t in piezoelectric buzzer Digital Communicator Specifications Supports major communication formats including SIA and Contact ID Event initiated personal paging Three programmable telephone numbers Two...

Страница 6: ...the PC5928 Audio Interface Module PC5921 EXT Door Box Audio Station Used in conjunction with the PC5928 Audio Interface Module PC5921 EXT R Door Box Audio Station Used in conjunction with the PC5928...

Страница 7: ...out the Programming Worksheets completely before attempt ing to program the system Step 10 Testing the System Test the panel thoroughly to ensure that all features and func tions are operating as pro...

Страница 8: ...These lines may incorporate a voice filter which dis connects the line if anything other than fax signals are detected resulting in incomplete transmissions 2 3 Keybus Operation and Wiring The Keybus...

Страница 9: ...les are supervised upon installation Supervision is enabled at all times so that the panel can indi cate a trouble if a module is removed from the system To check on which modules are currently connec...

Страница 10: ...one input to which a device such as a door contact can be connected This eliminates the need to run wires back to the control panel for every device To install the keypad open the keypad plastic by re...

Страница 11: ...ing Stay arming please see section 3 5 Function Keys on page 10 3 3 Automatic Arming The system can be programmed to Auto Arm at a specific time every day if it is in the disarmed condition In order f...

Страница 12: ...odule being powered by a PC5204 you must also remove and then restore power to the PC5204 and any connected modules This ensures that any troubles present on the module are correctly logged and or ann...

Страница 13: ...ult These settings can be changed Access Code Attributes There are three access code attributes which can be pro grammed for each code To program each attribute enter 5 Master Code 9 to enter the attr...

Страница 14: ...the panel will ignore only one activation of a Delay zone When the Delay zone is secured the panel will end the two minute quick exit delay If a second Delay zone is tripped or if the zone is not res...

Страница 15: ...anual NOTE This function key cannot be programmed for PC55XX LED keypads with software version 1 0 19 7 3 Command Output Option 3 A valid access code may need to be entered 20 For future use 21 7 4 Co...

Страница 16: ...the key to exit the section Select that section again and re enter the information correctly NOTE There must be one digit in each box in the program ming section in order for the change to be valid 4...

Страница 17: ...y pad When a programming section is entered the keypad will immediately display the first digit of information programmed in that section The keypad displays the information using a binary format acco...

Страница 18: ...ry time expires no alarm will be generated 02 Delay 2 Zone The Delay 2 entry delay time can be set independently of Delay 1 in programming section 005 System Times 03 Instant Zone This zone type will...

Страница 19: ...e trouble 23 Maintained Keyswitch Arm Zone When this zone is violated the system will arm When this zone is secured the system will disarm Tampers and faults will not arm disarm the system but only ac...

Страница 20: ...in and search for a dial tone for 5 seconds d the panel will then dial regardless of the presence of dial tone If there is no initial handshake recognized within 40 seconds the panel will then hang up...

Страница 21: ...ed to report events to the central station by sending the Reporting Code programmed for a par ticular event Reporting codes can be one or two digits and can use HEX digits A through F For a complete d...

Страница 22: ...Section 361 to 368 The following is a description of each reporting format Pulse Formats Depending on which pulse format is selected the panel will communicate using the following specifications 3 1 3...

Страница 23: ...e pager once Once the appro priate telephone number is dialed the panel will send the account number and Reporting Code followed by the key Hex C The panel has no way of confirming if the pager was ca...

Страница 24: ...ted Call Up option is enabled the user can have the panel initiate a call to the downloading computer by pressing 6 Master Code 6 The Download Access Code and Panel Identifier Code are for security an...

Страница 25: ...ed to indicate that an alarm has occurred before entering the premises The PGM attributes for this option programmed in Sections 141 to 154 differ from the standard selection of attributes Program whi...

Страница 26: ...outputs PGM attributes return to their default settings when you change PGM output options Please see the programming worksheets for a list of the default settings for each PGM out put type Care shou...

Страница 27: ...me expires Communication of the signal to central station is immediate If the A Key is pressed and held for two seconds the panel will sound the keypad beeps three times to verify activa tion The pane...

Страница 28: ...al applications Bell Squawk on Entry Delay may be enabled The panel will squawk the alarm output once every second until the entry delay expires or the system is dis armed If the Bell Squawk During Au...

Страница 29: ...estoral Reporting Codes Section 338 System Tampers Req Installer Reset Section 701 4 NOTE After enabling keypad tampers it is recommended to tamper and restore all keypads to ensure proper functioning...

Страница 30: ...5 31 Installer s Lockout If Installer s Lockout is selected a hardware default cannot be performed If a software default is performed all program ming will restore to factory default If Installer s L...

Страница 31: ...________________________________________________________________________________________________I Keypad 7 I_____________________________________________I I____________________________________________...

Страница 32: ...Keypads must be installed to use 24 hour Buzzer zones 001 Zone 1 8 Definitions Section 5 2 Zone Programming on page 14 Default Default 01 I_______I_______I Zone 1 04 I_______I_______I Zone 5 03 I____...

Страница 33: ...Status 05 System Armed Status 18 Stay Armed Status 06 Ready To Arm 19 Command Output 1 7 1 07 Keypad Buzzer Follow Mode 20 Command Output 2 7 2 08 Courtesy Pulse 21 Command Output 3 7 3 09 System Tro...

Страница 34: ...Arm Disarm Bell Squawk disabled 5 17 23 OFF I________I 2 Bell Squawk During Auto Arm No Bell Squawk During Auto Arm 5 18 24 OFF I________I 3 Bell Squawk On Exit Delay No Bell Squawk On Exit Delay 5 1...

Страница 35: ...Contact I D Partial Close Identifier is 5 Partial Close Identifier is 4 5 9 18 OFF I________I 5 8 For future use 020 Keypad Zone Assignments Section 2 11 Keypad Zones on page 6 NOTE Only one keypad m...

Страница 36: ...ion 001 Attribute 1 2 3 4 5 6 7 8 ON Audible Steady Chime Bypass Force Swing Tx Delay Wireless Zn OFF Silent Pulsed No No No No No No Zone Type 00 Null Zone N N N N N N N N 01 Delay 1 Y Y Y Y N Y N N...

Страница 37: ...1 11 I________I I________ I________ I________ I________ I________ I________ I________I 152 12 I________I I________ I________ I________ I________ I________ I________ I________I 153 13 I________I I_____...

Страница 38: ...nd Telephone Number 32 Digits Section 5 7 Communicator Telephone Numbers on page 17 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_...

Страница 39: ..._____I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I 342 Code 25 Code 26 Code 27 Code 28 Code 29 Code 30 Code 31 Code 32 I_______I_______I I_______I...

Страница 40: ..._____I General Zone Trouble Alarm I_______I_______I General Zone Trouble Restore I_______I_______I For future use 352 Test Transmission Reporting Codes Section 5 8 Communicator Reporting Codes on pg 1...

Страница 41: ...5 23 030 I_______I_______I_______I AC Failure Communication Delay 001 255 minutes 5 8 17 003 I_______I_______I_______I TLM Trouble Delay No of checks required valid entries 003 255 5 12 22 030 I______...

Страница 42: ...indow OFF I_______I 3 Call Back Enabled Call Back Disabled OFF I_______I 4 User initiated Call up Enabled User initiated Call up Disabled OFF I_______I 5 8 For future use 402 Downloading Computer s Te...

Страница 43: ...line Test Transmission in minutes Land line Test Transmission in days 5 14 23 OFF I_______I 4 1600 Hz Handshake Standard Handshake 5 9 18 OFF I_______I 5 ID Tone enabled ID Tone disabled 5 5 16 OFF I_...

Страница 44: ...BAD 3 Beeps Squawks 990 Installer Lockout Enable Section 5 31 Installer s Lockout on page 26 991 Installer Lockout Disable Section 5 31 Installer s Lockout on page 26 993 Restore LINKS2X50 Factory De...

Страница 45: ...der Supervisory Alarm Rest panel loses restores supervisory transmission over the Keybus from enrolled PC5132 module or keypads with zone inputs A R 1 43 UA 00 UH 00 328 Cross Zone Police Code Alarm t...

Страница 46: ...T 00 UJ 00 352 Periodic Test periodic system test transmission T 6 A2 RP 00 352 System Test 6 bell communications test T 6 A1 RX 00 352 LINKS Test LINKS test transmission T 6 A3 TX 00 353 Wireless Dev...

Страница 47: ...one 5 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I Default Zone 6 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I Default...

Страница 48: ...bled ON I_______I 2 A uxiliary Keys enabled A uxiliary Keys disabled ON I_______I 3 P anic Keys enabled P anic Keys disabled OFF I_______I 4 8 For future use 65 Fourth User Display Mask Default Option...

Страница 49: ...Label Broadcast All LCD programming is done per keypad If more than one LCD keypad are present on the system and the PC5400 receives labels labels pro grammed at one keypad can be broadcast to all oth...

Страница 50: ...46 NOTES...

Страница 51: ...6 of the Telecommunications Act 1981 6 It is important that the installer verifies the correct operation of stored telephone numbers subsequent to their entry 7 The connection to this equipment consis...

Страница 52: ...e 18 New PGM Output Type 26 Battery Test See 5 11 PGM Output Options on page 20 New Zone Types 27 Push to Set 28 24 Hr Bell Buzzer See 5 2 Zone Programming on page 14 New Options Troubles are Latching...

Отзывы: