[10] Zone Definitions 

(4.2 “Setting up PC5502Z2 Zones and Zone Options”  on page 6)

Valid entries: 00 - 04

Zone 1

Zone 2

Default = 01

Default = 02

I_______I_______I

I_______I_______I

[20] Entry and Exit Times 

(4.4 “Programming Entry and Exit Times”  on page 9)

Valid entries: 001 - 255 seconds

Entry Time

Exit Time

Default = 030

Default = 120

I_______I_______I_______I

I_______I_______I_______I

[25] Master Code 

(4.7 “Programming the Master Code”  on page 11)

Default = 1234

I_______I_______I_______I_______I

Enter:

To select this zone definition:

00

Zone not used

01

Delay 1

02

Instant

03

Interior

04

Stay/Away

05

24 Hour Burglary

Содержание PC5502Z2

Страница 1: ...n on the limitations as to liability of the manufacturer The entire manual should be carefully read PC5502Z2 Installation Manual 1999 Digital Security Controls Ltd 1645 Flint Road Downsview Ontario Ca...

Страница 2: ...need to be replaced this monitor may fail to operate as expected Regular testing and maintenance will keep the system in good operating condition Compromise of Radio Frequency Wireless Devices Signals...

Страница 3: ...e PC5502Z2 to a Keypad Zone on page 14 Program the keypad zone assignment in the main panel Installer s programming at the system keypad Refer to your system s Installation Manual for instructions Key...

Страница 4: ...oses other than those for which it was designed damage from improper maintenance damage arising out of any other abuse mishandling or improper application of the products Digital Security Controls Ltd...

Страница 5: ...ad PC5508Z PC5516Z PC5532Z or LCD5500Z to use for programming the main control panel and for monitoring the status of the entire system Mount the system keypad in an area accessible only by personnel...

Страница 6: ...labels 2 2 Mounting You should mount the keypad where it is accessible to designated points of entry and exit Once you have selected a dry and secure location perform the following steps to mount the...

Страница 7: ...tions outlined in your system s Installation Manual NOTE The PC5502Z2 zones will follow the end of line supervision option selected for the main panel Please refer to your panel s Installation Manual...

Страница 8: ...ssigned to slot 11 by default You must assign each keypad to its own slot 11 to 18 for it to be properly supervised by the system NOTE PC5502Z2 keypads should only be enrolled on partition 1 To enroll...

Страница 9: ...D5500Z or DLS software You cannot enter the programming sections for the main panel from PC5502Z2 keypads 4 1 How to Program the PC5502Z2 This section describes how to program a PC5502Z2 It is a good...

Страница 10: ...s pro gramming NOTE After you exit from Installer s programming all bypassed zones will be cleared unbypassed 4 2 Setting up PC5502Z2 Zones and Zone Options Each PC5502Z2 keypad can supervise two zon...

Страница 11: ...med the PC5502Z2 will wait the programmed amount of time and then pass the alarm on to the main panel The main panel will then immediately communicate the alarm to the central station The bell will so...

Страница 12: ...tion is on interior by default When this option is turned on zones programmed as type 04 will work as described in the Stay Away zone description page 6 When this option is turned off delay zones prog...

Страница 13: ...ds for the exit time The keypad sounds 4 quick beeps 5 If you want you can now program another section To exit programming press 4 5 Programming Quick Arm and Quick Exit Options You can program the fo...

Страница 14: ...tay Arm 01 Away Arm 02 Chime 04 Sensor Reset 09 and Quick Exit 10 To use a function press and hold the appropriate key for two seconds Users may also need to enter an access code after pressing the fu...

Страница 15: ...Programming by pressing 8 Installer s Code 2 Enter one of the following sections to turn on the access code requirement for a par ticular function key 45 for Function Key 1 46 for Function Key 2 47 fo...

Страница 16: ...ram the amount of time the alarm will sound locally in 50 Local Alarm Duration Timer Program an amount of time from 001 to 255 seconds If you program 000 seconds the PC5502Z2 will not sound a local al...

Страница 17: ...n now enter another programming section or to exit program ming press 32 Keypad Blanking This option is off by default If the Keypad Blanking option is turned on the PC5502Z2 will turn off all keypad...

Страница 18: ...olled all installed PC5502Z2 keypads into indi vidual slots See Enrolling the PC5502Z2 on page 4 To assign the PC5502Z2 to a keypad zone 1 At the system keypad not the PC5502Z2 keypad enter Installer...

Страница 19: ...or each system zone For each PC5502Z2 zone enter a 2 digit zone definition We recom mend that you program each PC5502Z2 keypad zone as a 24 Hour Burglary zone 11 This will ensure that alarm informatio...

Страница 20: ...ling the PC5502Z2 on page 4 Valid entries are 11 18 i e enter 11 for slot 1 12 for slot 2 etc Default 11 NOTE PC5502Z2 keypads should only be enrolled on partition 1 Slot I_______I_______I 01 05 Funct...

Страница 21: ...4 Programming Entry and Exit Times on page 9 Valid entries 001 255 seconds Entry Time Exit Time Default 030 Default 120 I_______I_______I_______I I_______I_______I_______I 25 Master Code 4 7 Programmi...

Страница 22: ...I_______I OFF 4 6 10 48 Function Key 4 Requires Code I_______I OFF 4 6 10 49 Function Key 5 Requires Code I_______I OFF 4 6 10 50 Local Alarm Duration Timer 4 8 Setting Up the PC5502Z2 to Sound Alarm...

Страница 23: ...need to be replaced this monitor may fail to operate as expected Regular testing and maintenance will keep the system in good operating condition Compromise of Radio Frequency Wireless Devices Signals...

Страница 24: ...n on the limitations as to liability of the manufacturer The entire manual should be carefully read PC5502Z2 Installation Manual 1999 Digital Security Controls Ltd 1645 Flint Road Downsview Ontario Ca...

Отзывы: