PC5020 Module Compatibility
Module
Compatible?
Comments
Classic Escort (VPM-1)
No
DLM-1
No
DLM-4 v1.x
No
DLM-4 v1.0L
Yes
DLM-7
No
Escort5580 v3.0
Yes
Fully compatible with Power864.
LCD5500 v1.X
Yes
No Keypad zone support. Some display messages not supported. Can
only be used on Partition 1 and Partition 2, and the first 32 zones.
LCD5500Z v2.X
Yes
Can only be used on Partition 1 and Partition 2, and the first 32 zones.
LCD5501Z v1.x
Yes
Can only be used on Partition 1 and Partition 2, and the first 32 zones.
LCD5500Z v3.X
Yes
Fully compatible with Power864.
LCD5501Z v2.x
Yes
Fully compatible with Power864.
LCD5501Z32-433
Yes
Fully compatible with Power864.
LCD600
No
LED615
No
Links1000 v3.0
Yes
Links2150 v1.3W
Yes
Some events not supported (reporting zones 33-64 and partions 3-8).
Links2450 v1.3
Yes
Some events not supported (reporting zones 33-64 and partions 3-8).
PC-16 Out
No
PC5100
Yes
Can only add addressable devices to the first 32 zones.
PC5108 v1.X
Yes
Can only support the first 32 zones. Enrolls as two expander modules -
each module will use up two supervisory slots.
PC5108L
Yes
Can only be assigned zones from 9 to 32. Will not support zones 33 to
64. Camera scripts can only be run for zones 9 to 32. Enrolls as two
expander modules and uses two supervisory slots.
PC5108 v2.x
Yes
Fully compatible with Power864.
PC5132 v1.X
Yes
No support for Wireless Keys, Pendants or Handheld Keypads. Only the
first 32 zones can be used as wireless zones.
PC5132 v2.X
Yes
No identified Wireless Keys support. Only the first 32 zones can be
used as wireless zones.
PC5132 v3.X
Yes
Only the first 32 zones can be used as wireless zones.
PC5200
Yes
Fully compatible with Power864.
PC5204
Yes
Fully compatible with Power864.
PC5208
Yes
Fully compatible with Power864.
PC5320
Yes
Fully compatible with Power864.
PC5400 Printer/DVACS
Module v1.X to v2.1
Yes
Some printing messages not supported. Some events not supported.
PC5400 Printer/DVACS
Module v2.2
Yes
Some events not supported.
PC55XX
Yes
No Keypad zone support. Can only be used on Partition 1 and Partition
2, and the first 8, 16, or 32 zones.
PC55XXZ
Yes
Can only be used on Partition 1 and Partition 2, and the first 8, 16, or
32 zones.
PC5506
No
PC5509
No
PC5700 v1.X
Yes
Enrolls as two expander modules - each module will use up two super-
visory slots.
PC5700 v2.0
Yes
Fully compatible with Power864.
PC5720
Yes
Enrolls as two expander modules - each module will use up two super-
visory slots.
PC5908
No
PC5928
No
PC5936
Yes
Fully compatible with Power864.
Skyroute v2.2
Yes
Some events not supported (reporting zones 33-64 and partitions 3-8).
SL-XX
No
T-Link Yes For UL Grade AA / ULC Level 3
©2002 Digital Security Controls Ltd.
Toronto, Canada •
www.dsc.com
Technical Support: 1-800-387-3630
Printed in Canada 29005907 R004