A p p e n d i x A : R e p o r t i n g C o d e s
The following tables contain Contact ID and Automatic
SIA format reporting codes. For more information on
reporting code formats and notes about individual
reporting codes,
(see section 5.6 ‘Communicator Program-
ming’ PWS Sect 6).
Contact ID
The first digit (in parentheses) will automatically be sent
by the control panel. The second two digits are pro-
grammed to indicate specific information about the sig-
nal. For example, if zone 1 is an entry/exit point, you
could program the event code as [34]. The central station
would receive the following:
*BURG - ENTRY/EXIT - 1 where the ’1’ indicates which
zone went into alarm.
SIA Format - Level 2 (Hardcoded)
The SIA communication format used in this product fol-
lows the level 2 specifications of the SIA Digital Commu-
nication Standard - October 1997. This format will send
the account code along with its data transmission. The
transmission will look similar to the following at the
receiver:
N Ri01
BA 01
N
= New
Event
Ri01 =
Partition /Area Identifier
BA
= Burglary
Alarm
01
= Zone
1
NOTE:
A system event will use the Area Identifier Ri00.
Section #
Reporting Code
Code Sent When...
Dialer
Direction*
Automatic
Contact ID
Codes
SIA Auto Rep
Codes**
[320]-[323]
Zone Alarms
Zone goes into alarm
A/R
See Table 3
See Table 3
[324]-[327]
Zone Restorals
Alarm condition has been restored
A/R
[328]
Duress Alarm
Duress code entered at keypad
A/R
(1) 21
HA-00
[328]
Opening After Alarm
System disarmed with alarm in memory
A/R
(4) A6
OR-00
[328]
Recent Closing
Alarm occurs within two minutes of system arming
A/R
(4) 59
CR-00
[328]
Zone Expander Supervisory
Alarm/Rest.
Panel loses/restores supervisory transmission over the Keybus
from zone expansion modules, or keypads with zone inputs
A/R
(1) 43
UA-00/UH-00
[328]
Cross Zone (Police Code)
Alarm
Two zones on the same partition go into alarm during any
given armed-to-armed period (incl. 24-hr zones)
A/R
(1) 4A
BM-00/BV-00
[328]
Burglary Not Verified
This reporting code will be sent after the Burglary Verified Timer
expires after a zone alarm occurs.
A/R
(3) 78
BG-00
[328]
Alarm Cancelled
This reporting code will be sent if a valid access code is entered
during the Alarm Cancel window
A/R
(4) A6
BC-00
[329]
[F] Key Alarm/Restoral
Keypad fire alarm (alarm and restoral reporting codes sent
together)
A/R
(1) 15
FA-00/FH-00
[329]
[A] Key Alarm/Restoral
Keypad auxiliary alarm (alarm and restoral reporting codes sent
together)
A/R
(1) AA
MA-00/MH-00
[329]
[P] Key Alarm/Restoral
Keypad panic alarm (alarm and restoral reporting codes sent
together)
A/R
(1) 2A
PA-00/PH-00
[329]
Aux Input Alarm/Restoral
Option#23/24
: a panic button wired to PGM 2 is pressed/
access code is entered
Option #04:
a 2-wire smoke detector wired to PGM 2 goes
into alarm/alarm is cleared.
A/R
A/R
(1) 4A
(1) 11
UA-99/UH-99
FA-99/FH-99
[330]-[337]
Zone Tamper/Restoral
Zone is tampered / Tamper condition restored
T/R
(1) 44
TA-ZZ/TR-ZZ
[338]
General System Tamper/Rest.
Enrolled module with tamper inputs has a Tamper alarm/all
module Tampers restored
T/R
(1) 45
TA-00/TR-00
[338]
Keypad Lockout
Maximum number of incorrect access codes has been entered
at a keypad
T/R
(4) 21
JA-00
[339-341]
Closings
System armed (user 01-34, 40-42 indicated)
O/C
(4) A2
CL-UU
[341]
Partial Closing
One or more zones bypassed when system armed
O/C
(4) 7A
CG-ZZ
[341]
Special Closing
Closing (arming) using one of the following methods: quick
arm, auto-arm, keyswitch, function key, maintenance code,
DLS software, wireless key
O/C
(4) AA
CL-00
[341]
Late to Close
Whenever the auto-arm pre-alert sounds (if the Late to Close
option is enabled)
O/C
(4) A4
CI-00
[342-344]
Openings
System disarmed (user 01-34, 40-42 indicated)
O/C
(4) A2
OP-UU
[344]
Auto-arm Cancellation
Auto-arm cancelled
O/C
(4) A5
CE-00
* A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
** UU = user number (user01-42); ZZ = zone number (01-64)